Positioning of the Thermostat Phial in NFG 307 from

Serial

No. 501-----

In order to ensure the proper functioning of the thermostat 90

mm of the free end of the capillary tube is to serve as thermostat
phial.

In case of failing thermostat functioning and a possible
replacement of the thermostat, be sure that the phial part is
placed sufficiently far into the cabinet. This can be done
visually by removing the air duct.

Uprights with curved doors

Dismount the phial tube and straighten out the phial.
Draw off the insulation, if any, around the phial.

After the plug has been removed from the socket, remove the

cover for the top panel and the electrical unit simultaneously.
Remove the thermostat knob, nut and thermostat wiring and
draw the phial out of the mounting pipe behind the electrical
unit.
Install the new thermostat in reverse order.