Read operations, Thresholds during a read operation -8 – Exabyte EXB-8505 8mm User Manual

Page 63

Advertising
background image

Read Operations

Figure 3-2 provides a high-level overview of the tape drive’s flow of
data during a read operation.

The process for reading logical blocks of user data is outlined below.

¬

The tape drive reads data from tape, uses ECC to correct errors
as necessary for each physical block, and transfers data to the
data buffer. The read operation continues until the buffer is full
and tape motion stops.

­

If the data has not been compressed, the data goes directly from
the data buffer to the SCSI bus.

If the data has been compressed, the data goes from the data
buffer to the decompression circuit to be decompressed. Then,
the decompressed data is sent to the SCSI bus.

In either case, the 2-byte logical block CRC, which was
appended when the data was written, is again verified. This
final integrity check assures that all block reconstruction and
decompression was successful.

Uncompressed data

SCSI

bus

1

Decompression

circuit

Data to be

decompressed

Data
buffer

Data read from tape

Tape

2

Figure 3-2 Data flow during a read operation

May 1994

EXB-8205 and EXB-8505

3-7

(Standard and XL)

3 Functional Description

Advertising