Sis configuration and contr ol, cont’d – Extron electronic RSB 126 User Manual

Page 23

Advertising
background image

SW USB Series • SIS Configuration and Contr

ol

SIS Configuration and Contr

ol, cont’d

4-4

SW USB Series • SIS Configuration and Contr

ol

4-5

Command

ASCII Command

(host to unit)

Response

(unit to host)

Additional description

Firmware version, part number, and information requests

Request information

I

Chn

X!

• InACT

X$

• OutACT

X$

• Emul

X%

X^

]

Show the selected input and output.

X$

= Activity of all inputs and outputs

For SW USB Plus only:

X%

= Mouse emulation switch position

X^

= Keyboard emulation switch position

For

X%

and

X^

: 0 = off (down); 1 = on (up).

Request part number

N

60-95n-nn

]

Show the SW USB part number.
SW2 = 60-952-01, SW4 = 60-953-01,
SW4 USB Plus = 60-954-01.

Query firmware version

Q

n.nn

]

Show firmware version, expressed to the second
decimal place.

Example:

Q

1.01

]

Query version and build

*Q

n.nn.nnnn

]

Show firmware version and build number.

Reset

Reset

E

ZXXX

}

Zpx

]

Reset the switcher to factory default values.

Upload firmware

Upload firmware

E

Upload

}

...go
Upl

]

Upl appears after the upload is complete.

Command/response table for SIS commands

Command

ASCII Command

(host to unit)

Response

(unit to host)

Additional description

Input selection

Select input

X!

!

Chn

X!

]

Select input

X!

for both the SW USB and the

attached A/V switcher (if any).

Select SW USB input only

X!

^

USB

X!

]

Select input

X!

on the SW USB only (not passed

through).

Configure RS-232 pass-through

Send input selection commands
via contact closure, front panel,
or the RS-232 interface

E

0LOOP

}

Loop0

]

Input selection commands (only) issued via the
front panel, contact closure, or the RS-232 interface
are sent to an attached A/V switcher via the RS-232
Pass Thru port.

Send SIS commands via
computer RS-232 interface

E

1LOOP

}

Loop1

]

All available commands issued from an RS-232
interface can be performed by the SW USB and
passed through to a connected A/V switcher.

View loop out setting

E

Loop

}

Loop

X#

]

View pass-through setting

X#

. For

X#

:

0 = Input selection commands can be issued
through contact closure, the front panel, or
RS-232. (Loop 0 mode)
1 = All supported SIS commands can be issued
through the RS-232 interface. (Loop 1 mode)

Front panel lockout

Enable executive mode

1X

X#

]

Lock the front panel.

Disable executive mode

0X

X#

]

Unlock the front panel.

Lockout status

X

X#

]

Show executive mode on/off status.

Command/response table for SIS commands (continued)

Advertising
This manual is related to the following products: