Contact closure control, Controlling an extron a/v switcher in loop 0 mode, Connecting multiple sw usb switchers in a system – Extron electronic RSB 126 User Manual

Page 15: Connecting multiple sw usb switchers in a system, Installation, cont’d

Advertising
background image

SW USB Series • Installation

Installation, cont’d

2-12

SW USB Series • Installation

2-13

PC

Host Port

SW USB

Extron

A/V Switcher

2

3

5

RX

RX

TX

TX

TX

Connections for RS-232 loop-through

Contact Closure Control

Contact closure provides another method of input selection.

To enable input selection by contact closure, you can connect a

push-button contact closure device (such as Extron’s CCR 2BLB,

CCR 4BLB, or CCR 204) to the SW USB’s Contact port.
Alternatively, you can manually short one of the pins to ground

(the ground [_] pin is pin 3 for SW2 and pin 5 for SW4 models).

Pin 1 selects input 1, pin 2 selects input 2, etc.

Controlling an Extron A/V switcher in Loop 0 mode

For applications in which the SW USB is connected to an Extron

A/V switcher that can be controlled via RS-232, input selection

on both switchers can be done by contact closure (as well as

by the SW USB front panel buttons and the RS-232 interface).

To select inputs on the A/V switcher via contact closure, the

SW USB must be in Loop 0 mode (in other words, the SIS

command

E

LOOP0

}

has been issued).

If the SW USB is in Loop 0 mode and an Extron A/V switcher

is connected to the RS-232 Pass Thru port, an input selection

command issued via contact closure selects the same input on

both the SW USB and the connected switcher.

USB SWITCHING INPU

T

Tx

Tx Rx

RS-

232

CONT

AC

T

1

2

3

4

RS

-232

PASS THRU

USB OUTPUT HUB

USB

3

USB

1

PC

1

PC

2

PC

3

PC

4

USB

2

US

B 4

1.5A MA

X

12V

POWER

+

100-240V

0.2A

50-

60H

z

REMOT

E

INPUTS

1

2

3

4

OUTPUT

OUTPUT

L

R

SW6 VGA Ar

s

Extron
SW4 USB

USB Switcher

RS-232 Loop Out

Contact Closure

Extron
CCR 4BLB

Controller Module

Extron
SW4 VGA Ars

VGA/Audio Switcher

1

2

3

4

Using the SW USB with a contact closure device and
an A/V switcher

To configure the SW USB for contact closure control of an A/V

switcher,
1

.

If desired, connect a contact closure device to the SW USB’s

Contact port.

2

.

Connect the SW USB’s RS-232 Pass Thru port to the A/V

switcher’s RS-232 port.

3

.

Issue the SIS command E 0LOOP} to the SW USB to

enable Loop 0 mode.

Connecting Multiple SW USB Switchers in a

System

The USB specification states that a maximum of five hubs can be

connected in a series; therefore, no more than five SW USBs can

be cascaded in a series.

C

Do not exceed five cascaded hubs and a total of 127

peripheral devices in the entire system.

The diagram on the next page shows an example of SW USBs

and peripheral output devices daisy-chained from a single host.

Advertising