Selecting an input using contact closure, Selecting an input using sis commands, Sis command processing in loop 1 mode – Extron electronic RSB 126 User Manual

Page 18: Sis command processing in loop 1 mode -5, Operation, cont’d

Advertising
background image

SW USB Series • Operation

Operation, cont’d

3-4

SW USB Series • Operation

3-5

Selecting an input using contact closure

Use one of the following methods to select an input via contact

closure:

Using a contact closure device:

If a two- or four-button

contact closure device is connected to the SW USB’s

Contact port, press the button on the device that

corresponds to the SW USB input that you want to select

(the first button on the left selects input 1, the second

button selects input 2, etc.).

Using a jumper wire:

On the Contact port, insert one end

of a small piece of wire into the ground (_) port and the

other end into the port with the desired input number (1, 2,

3, or 4).

Using an IR 102:

Refer to your IR 102 User’s Manual for

this procedure.

Selecting an input using SIS commands

You can also select an input via an RS-232 connection, using SIS

commands. See chapter 4, “SIS Configuration and Control,” for

a list of available SIS commands and their explanations.
If an Extron A/V switcher is connected to the RS-232 Pass

Thru port, the SIS commands that you enter can also be passed

through to the connected switcher, even if the connected

switcher has more inputs than the SW USB (see the next section).

Issuing commands to an Extron A/V switcher via

the RS-232 Pass Thru port

You can configure the SW USB to pass commands through

the RS-232 Pass Thru port to a connected A/V switcher in the

following modes:

Loop 1 mode:

SIS commands that are issued to the

SW USB via an RS-232 interface (such as HyperTerminal)

on a computer or control system connected to the

SW USB’s RS-232 port can be passed through to an A/V

switcher connected to the RS-232 Pass Thru port.

Loop 1 mode is the default mode. If you need to switch

the SW USB to this mode, enter the SIS command

E1

LOOP

}

.

Loop 0 mode:

The input selection SIS command

X!

!

(where

X!

is the input number) can be issued to the

SW USB and the connected A/V switcher via the buttons

on the SW USB front panel, contact closure, or the RS-232

interface.

To enable Loop 0 mode, enter the SIS command

E

0LOOP

}

.

The following table summarizes the two loop modes:

Mode

SIS commands issued via:

SIS command to enable

Loop 0

Contact closure, front panel,
or RS-232 interface (Input
selection SIS command

X!

! only)

E

0LOOP

}

Loop 1

RS-232 interface*

E

1LOOP

}

* See the command/response table in chapter 4, “SIS

Configuration and Control,” for an explanation of all supported

SIS commands.

SIS command processing in Loop 1 mode

When an A/V switcher is connected to the RS-232 Pass Thru

port and Loop 1 mode is enabled, the available SIS commands

are processed in one of the following ways:

Passed through to the A/V switcher without being acted

on by the SW USB

Performed by the SW USB and not passed through to the

A/V switcher

Performed by the SW USB and passed to the A/V switcher,

which also performs them. This applies only to the input

selection command

X!

!.

The table on the next page shows how the SIS commands are

handled by an SW USB with a connected A/V switcher. (Unless

otherwise indicated, commands are not case-sensitive.)

Advertising
This manual is related to the following products: