SW USB Series • Operation

Operation, cont’d

3-6

SW USB Series • Operation

3-7

SIS

Command

SW USB Function

SW USB Response to Host

!

Performed and passed through

Chn

X!

]

^

Performed, not passed through

USB

X!

]

E

(any)

Performed, not passed through

See the SIS command table.

X

Performed, not passed through

Exe

X#

]

N

Performed, not passed through

60-95n-01

Q

Performed, not passed through

n

.nn

*Q

Performed, not passed through

n

.nn.nnnn

I

Performed, not passed through Chn

X!

•InACT

X$

OutACT

X$

]

0V – 100V

Passed through, not performed*

CMD

]

&

Passed through, not performed*

CMD

]

%

Passed through, not performed*

CMD

]

1B, 0B

Passed through, not performed*

CMD

]

1M, 0M

Passed through, not performed*

CMD

]

1Z, 0Z

Passed through, not performed*

CMD

]

$

Passed through, not performed*

CMD

]

*

For explanations of commands that are passed through to the

A/V switcher and not performed by the SW USB, refer to your

A/V switcher’s user’s manual.
Example:

When a control system issues an SIS input selection

command of 1! (Select input 1), 2! (Select input 2), 3! (Select

input 3), or 4! (Select input 4), the SW USB switches to the

corresponding input. In addition, the SW USB passes the SIS

input selection command through the RS-232 Pass Thru port,

causing the same input to be selected on the A/V switcher.
The following SIS commands can not be passed through to the

A/V switcher:

Information requests:

View part number (N) and Request

information (I)

Change loop mode:

E

nLOOP

Upload firmware:

E

Upload

See the SIS Command/Response table in chapter 4, “SIS

Configuration and Control,” for explanations of SIS commands

that are performed by the SW USB.

Sending commands to an A/V switcher using contact

closure

In Loop 0 mode, you can select an input on the SW USB by

shorting the equivalent pin on the Contact port to ground (either

by pressing a button on a connected contact closure device or by

connecting a jumper between pin 1, 2, 3, or 4 and

_

[ground]).

Shorting the pin to ground issues an input selection command to

the SW USB, which passes the SIS command through its RS-232

Pass Thru port to the A/V switcher. The switcher then switches

to the equivalent input.
For example, if you wanted to select input 1 on the

A/V switcher, you would short pin 1 to ground on the

SW USB Contact port. The SW USB switches to input 1 and,

simultaneously, the RS-232 Pass Thru port passes the SIS

command 1! to the A/V switcher, which also switches to input 1.
The following table shows the SIS commands that are issued

when inputs are selected by contact closure:

Contact closure
selection

SIS command sent
via RS-232 Pass Thru

Function on the
A/V Switcher

Pin 1 to

_

1!

Select input 1

Pin 2 to

_

2!

Select input 2

Pin 3 to

_

3!

Select input 3

Pin 4 to

_

4!

Select input 4

N

When the SW USB is operating in Loop 0 mode,

pressing one of its front panel input buttons or issuing

the SIS command

X!

! also selects the same input on the

A/V switcher.

Enabling front panel lockout (executive mode)

Executive mode disables all front panel controls, locking out

the user from those functions. Putting the switcher in this

mode enhances security by protecting against inappropriate or

accidental changes to settings. When the SW USB is in executive

mode, RS-232 and contact closure remain available.
To lock the front panel, press and hold Input buttons 1 and

2 simultaneously for 5 seconds, then release them. The red

Exec Mode LED on the front panel lights, indicating that

executive mode is enabled.