Careful handling and use of electrical power tools, Operation, Before first use – Parkside PHP 500 A1 User Manual

Page 7: Preparing the tool for use

Advertising
background image

8 GB

b)

To avoid the danger of injury,

burning and damage to he-
alth:

DANGER OF BURNS! The glue

and the nozzle can reach tempera-
tures of 200 °C. Do not touch the

nozzle or the glue. Keep other people and
animals away from the hot glue. On contact
with the skin, hold the affected part under run-
ning cold water for several minutes. Do not try
to
remove the glue from the skin.

4. Careful handling and use

of electrical power tools

a)

Pull the mains plug from the socket
before you make any adjustments to
the device, change accessories or when
the device is put away. This precaution is
intended to prevent you from unintentionally
starting the device.

b) When not in use always ensure that

electrical power tools are kept out of
reach of children. Do not let anyone
use the device if he or she is not
familiar with it or has not read the
instructions and advice. Electrical power
tools are dangerous when they are used by
inexperienced people. Let the device cool
down completely before putting it away. The
hot nozzle can cause damage.

c) Look after the device carefully. Check

that moving parts are working pro-
perly and move freely. Check for any
parts that are broken or damaged
enough to detrimentally affect the
functioning of the device. Have dama-
ged parts repaired before you use the
device. Many accidents have their origins in
poorly maintained electrical power tools.

d) Always work with the mains lead leading

away from the rear of the device.

©

Operation

©

Before first use

Preparing the glue site:

½

Do not use inflammable solvents to clean the
glue site.

½

The ambient temperature and temperature of
the materials to be glued must be not less than
+ 5° C and not warmer than + 50° C.

½

The glue sites must be clean, dry and free of
grease.

˽

Smooth surfaces should be roughened before
gluing.

˽

Warm any materials that are prone to cool
down quickly (e.g. steel) to improve the bond
with the glue.

˽

Screw on the appropriate nozzle

8

and fit

the wire stand

6

.

©

Preparing the tool for use

Working with the mains lead connected:
1. Connect the mains lead

11

to the glue gun

connection

10

(see Fig. F).

Insert the mains plug into the mains socket.

2. Fold forward the wire stand

6

.

Stand the device up.

3. Push a glue stick into the feed channel

1

.

4. Let the device heat up for about 4 minutes.

The device is now ready for use.

Cordless

working:

1. Connect the mains lead

11

to the charger

connection

3

.

Insert the mains plug into the mains socket.

2. Place the glue gun into the charger

4

.

3. Push a glue stick into the feed channel

1

.

4. Let the device heat up for about 4 minutes.

The device is now ready for use.

5. Repeat the heating-up procedure if the feed

switch becomes stiff or the outcoming glue
becomes viscous.

Safety notes / Operation