Replacing the power cable – Parkside PKO 270 A1 User Manual

Page 12

Advertising
background image

result of stiffness.

7.6 ON/OFF switch (Fig. 2)
Pull the ON/OFF switch (17) upwards to switch
on the compressor. To switch off the
compressor, press the ON/OFF switch down.

7.7 Adjusting the pressure: (Fig. 1,3).

You adjust the pressure on the pressure
gauge (5) using the pressure regulator (3).

The set pressure can be taken from the
quick-lock coupling (4).

The vessel pressure can be read on the
pressure gauge (6).

The vessel pressure can be taken from the
quick-lock coupling (20).

7.8 Adjusting the pressure switch (Fig. 1)
The pressure switch (2) is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar

7.9 Fitting the compressed air hose

(Fig. 1, 3)

Use the compressed air hose (14) if you intend
to carry out work at a greater distance from the
compressor. To do so, connect the nipple (H)
on the compressed air hose to one of the quick-
release couplings (4, 20). Then attach the
compressed air tool to the quick-release
coupling (G) on the compressed air hose.

8. Replacing the power cable

If the power cable for this equipment is
damaged, it must be replaced by the
manufacturer or its after-sales service or
similarly trained personnel to avoid danger.

9. Cleaning, maintenance,

ordering of spare parts and
storage

ƽ

Important.

Pull the power plug before doing any
cleaning and maintenance work on the
appliance.
Risk of injury by electric shock.

ƽ

Important.

Wait until the equipment has cooled down
completely. Risk of burns!

ƽ

Important.

Always depressurize the equipment before
carrying out any cleaning and maintenance
work. Risk of injury.

9.1 Cleaning

Keep the equipment free of dirt and dust as
far as possible. Wipe the equipment with a
clean cloth or blow it down with compressed
air at low pressure.

We recommend that you clean the
equipment immediately after you use it.

Clean the equipment regularly with a damp
cloth and some soft soap. Do not use
cleaning agents or solvents; these may be
aggressive to the plastic parts in the
equipment. Ensure that no water can get
into the interior of the equipment.

You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.

9.2 Maintenance work on the pressure

vessel (Figure 1)

Important. To ensure a long service life of the
pressure vessel (7), drain off the condensed
water by opening the drain plug (9) each time
after using. Release the vessel pressure.
Check the pressure vessel for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure
vessel. If you discover any damage, then
please contact the customer service workshop.

12

GB/

IE

Anleitung_4010365:_ 27.05.2010 13:15 Uhr Seite 12

Advertising