11. Possible causes of failure

Problem

Cause

Solution

The compressor does not
start.

1. No supply voltage.

2. Insufficient supply voltage.

3. Outside temperature is too

low.

4. Motor is overheated.

1. Check the supply voltage,

the power plug and the
socket-outlet.

2. Make sure that the

extension cable is not too
long. Use an extension cable
with large enough wires.

3. Never operate with an

outside temperature of
below +5° C.

4. Allow the motor to cool

down. If necessary, remedy
the cause of the overheating.

The compressor starts but
there is no pressure.

1. The non-return valve leaks.

2. The seals are damaged.

3. The drain plug for

condensation water (9)
leaks.

1. Replace the non-return

valve.

2. Check the seals and have

any damaged seals replaced
by a service center.

3. Tighten the screw by hand.

Check the seal on the screw
and replace if necessary.

The compressor starts,
pressure is shown on the
pressure gauge, but the
tools do not start.

1. Loose hose connections.

2. Leak in a quick-lock

coupling.

3. Insufficient pressure set on

the pressure regulator (3).

1. Check the compressed air

hose and tools and replace if
necessary.

2. Check the quick-lock

coupling and replace if
necessary.

3. Increase the set pressure

with the pressure regulator.