• Before each use, check the equipment,

cable and plug for damage.

• If the power cable for this equipment is

damaged, it must be replaced by the

manufacturer, a customer service agent

of the same or a similarly qualified per-

son in order to prevent hazards.

• Do not pull the plug from the socket by

the cable. Protect the cable from heat,

oil and sharp edges.

• Do not carry or fix the equipment by

the cable.

• Use only extension cables that are pro-

tected from spray water and designed

for outdoor use. Always fully unroll a

cable drum before use. Check the ca-

ble for damage.

• Before any work on the equipment,

during work breaks and in the case

of non-use, remove the plug from the

socket.

• The cross-section of the power sup-

ply cable must not be less than

2 x 2,5 mm².

• Wear sturdy footwear to protect

against electric shock.

• To protect against electric shock, oper-

ate the equipment only in an upright

position.

Start-up

In keeping with current regulations

a pressure cleaner must never be

operated off the drinking water

mains supply without a controllable

backflow preventer. A suitable back-

flow preventer in conformity with

EN 12729 type BA must be used.

Water that has passed through a backflow

preventer is classified as undrinkable.

A backflow preventer is available in spe-

cialist shops.

• Employ an ordinary garden hose for

the water intake and ensure sufficient

couplings are important for machine

safety. Use only high-pressure hoses,

fittings and couplings recommended by

the manufacturer.

• Use only original accessories and do

not carry out conversion work on the

equipment.

• Please read the notes in the operating

instructions on the topic of “mainte-

nance and cleaning”. Any measures

above and beyond these, particularly

opening the equipment, are to be car-

ried out by an authorised electrician.

In the case of repairs, always contact

our service centre.

Electrical safety:

Caution: to avoid accidents

and injuries from electric

shocks:

• The plug and socket of an extension

cable must be water-tight!

Unsuitable extension cables can

be dangerous as people can be

harmed by an electric shock!

• Protect the electric plug connections

against moisture.

• If there is a risk of flooding, fix the

plug connections in an area that is safe

from flooding.

• Ensure that the mains voltage matches

the specifications on the rating plate.

• Connection to the mains must be

carried out by an experienced electri-

cian and meet the requirements of

IEC 60364-1.

• The electrical installation shall be ac-

cording to national wiring rules.

• The device must only be connected to

a mains socket via a residual-current

circuit breaker (RCD) with a rated leak-

age current of not more than 30 mA.

Fuse: at least 13 ampere.