Parkside PHD 150 B2 User Manual

Page 47

Advertising
background image

47

GB

• The standard Vario nozzle (18) pro-

duces a flat wide jet particularly suited

for large surfaces.

Turn the tip of the nozzle left to reduce

the width of the jet. Turn the tip of the

nozzle right to expand the width of

the jet.

In the event of leaks in the

water system, switch off the

equipment immediately at

the on/off switch (10) and

disconnect the equipment

from the mains at the mains

power cord (6). Risk of elec-

tric shock! Start afresh with

making the water connec-

tions (cf. “Start-up / Opera-

tion” from point 4.).

If there is still air in the device,

please proceed as follows:

To vent the supply hose:

1. Remove the quick connector

for garden

hose adaptor

(13) on the water con-

nection (9) and open the water tap

until water comes out with no bubbles.

2. Switch off the water tap.

3. Connect the supply hose to the water

connection (9) on the equipment using

the quick connector for garden hose

adapter (13).

4. Fully open the water tap.

To vent the equipment:

5. Switch on the on/off switch (10) until

pressure has built up.

6. Switch off the on/off switch (10).

7. Press the on lever on the gun (1) until

the pressure has gone.

8.

Please repeat process 5. to 7. a few

times until there is no more air in the

device.

High-pressure / low-pressure

operation

The standard Vario nozzle (18) is designed

for either high-pressure or low-pressure

operation.

The standard Vario nozzle is set to high

pressure by default.

Push the tip of the nozzle forward to

change to low-pressure operation.

In this mode (low pressure), the unit will

automatically draw in cleaning agent from

the built-in tank (cf. “Using detergents”).

Push in the tip of the nozzle to change to

high-pressure operation.

B

• Lock / unlock the starting lever

(24) of the gun (1) by depressing

the locking knob (23).

Lock the starting lever (24) to

prevent the pressure cleaner

from being inadvertently / ac-

cidentally started.

Locked

Open

Interrupting operation

• Release the lever of the gun (1).

• During prolonged work intervals turn

off the pressure cleaner by its ON /

OFF switch (10).

If the equipment falls over,

switch off the equipment

immediately at the on/

off switch (10) and discon-

nect the equipment from the

mains at the mains power

cord (6).

Risk of electric

shock!

Only now should the

Advertising