Start�up, Gb mt – Parkside PHD 100 B2 User Manual

Page 42

Advertising
background image

42

GB MT

• Use only extension cables that are pro-

tected from spray water and designed

for outdoor use. Always fully unroll a

cable drum before use. Check the ca-

ble for damage.

• Before any work on the equipment,

during work breaks and in the case

of non-use, remove the plug from the

socket.

• The cross-section of the power supply

cable must not be less than 2 x 2,5

mm².

Start�up

In keeping with current regulations

a pressure washer must never be

operated off the drinking water

mains supply without a controlla-

ble backflow preventer. A suitable

backflow preventer in conformity

with EN 12729 type BA must be

used.

Water that has passed through a backflow

preventer is classified as undrinkable.

A backflow preventer is available

from specialist retailers.

• Employ an ordinary garden hose for

the water intake and ensure sufficient

length.

Setting up

B

• Screw the equipment side of the

high-pressure hose connection

(2) to the high-pressure hose con-

nection (3) on the equipment.

• Screw the gun side of the high-

pressure hose connection (1) to

the spray gun (10)

Electrical.safety:

Caution: to avoid accidents and

injuries from electric shocks:

• The plug and socket of an extension

cable must be water-tight!

Unsuitable extension cables can

be dangerous as people can be

harmed by an electric shock!

• Protect the electric plug connections

against moisture.

• If there is a risk of flooding, fix the

plug connections in an area that is safe

from flooding.

• Ensure that the mains voltage matches

the specifications on the rating plate.

• The electrical installation shall be ac-

cording to national wiring rules.

• Connection to the mains must be car-

ried out by an experienced electrician

and meet the requirements of IEC

60364-1.

• The device must only be connected to

a mains socket via a residual-current

circuit breaker (RCD) with a rated leak-

age current of not more than 30 mA.

Fuse: at least 13 ampere.

• Before each use, check the equipment,

cable and plug for damage.

• If the power cable for this equipment is

damaged, it must be replaced by the

manufacturer, a customer service agent

of the same or a similarly qualified per-

son in order to prevent hazards.

• Do not pull the plug from the socket by

the cable. Protect the cable from heat,

oil and sharp edges.

• Do not carry or fix the equipment by

the cable.

Advertising