130

Maintenance

5. Unplug the cord from the

TPU

connector.

6. Remove any paper from the sheet feeder and output tray, then remove the

paper support.

7. Close the output tray.

8. Lift up the scanner unit.

9. Remove the orange print head lock from its storage area and install it as shown

to prevent the print head from moving during transport. If you can’t find the
orange print head lock, tape the print head to the case.

Caution:
Be sure to remove the orange print head lock or tape after installing the
Stylus Photo RX600 in its new location.

10. Close the scanner unit carefully until it clicks back into place.

11. Repack the Stylus Photo RX600 and its attachments in the original box using

the protective materials that came with them.

Caution:
Keep the Stylus Photo RX600 level as you transport it.

After transporting the Stylus Photo RX600, remove the orange print head lock or
tape securing the print head, unlock the transportation lock securing the scanner
carriage, and print a test copy. If you notice a decline in quality, clean the print
head (see page 121); if output is misaligned, align the print head (see page 128).

SP RX600 Users Guide.book Page 130 Thursday, January 29, 2004 1:08 PM