Levelling
Level the appliance by loosening or

tightening the feet. Once in the right

position fix the feet by pushing the nuts

against the base of the case. Accurate

levelling will prevent vibration, noise and

displacement of the appliance during

operation.
Some vibration is inevitable, especially if

placed on a wooden floor. Wooden

floors are particularly susceptible to

vibrations. If possible always place the

appliance on a solid floor.

IMPORTANT:
The distance from the floor to the

highest part of the hose should be

between 60 to 90 cm. (It is advised to

be between 60 and 70 cm). The hose

must not be bent nor twisted to avoid

clogging. Should a prolongation of the

discharging hose be unavoidable this

must never surpass 1.5 m and must be

of the same diameter as the original

hose.
Make sure the hoses are not too tense.

Electrical connection
This machine is designed to operate on

a 230 V, single-phase, 50 Hz supply.
Check that your domestic electrical

installation can take the maximum load

required (2.1 kW), also taking into

account any other appliances in use.
The applicable rules for electrical

security require an adequate

earthing. The plug of the appliance

is provided with such a device.

The manufacturer declines any

responsibility for damage or injury

through failure to comply with the above

safety precaution. Should the appliance

power supply cable need to be

replaced, this should be carried out by

our Service Centre.

Please ensure that when the appliance is

installed the power supply cable is easily

accessible.