Enterasys Networks 8000/8600 User Manual

Page 34

Advertising
background image

Hardware Overview

22

Enterasys X-Pedition 8000/8600 Getting Started Guide

Options Available

This module operates with the following APHYs (you may purchase them separately from the
module) connected to the outside world. For information about these APHYs, consult the Enterasys
Networks web site.

Caution: The X-Pedition-APHY-21 and X-Pedition-APHY-29IR use Class 1 Lasers. Do not use
optical instruments to view laser output. The use of optical instruments to view laser output
increases eye hazard.

Note:

Before you can remove an APHY, Hot Swap the host ATM module.

The ATM line card has two available slots. Each slot accepts the following PHY interface modules:

Port type

Specification

APHY-67

1 DS-3/T-3 interface (BNC Coax); see APHY-67 and APHY-77

on page 81

for attaching cables

75 coaxial (RG-59B or equivalent) terminated with 75-ohm BNC
connectors

Maximum of 450 ft (137 m) of cable

APHY-77

1 E-3 interface (BNC); see APHY-67 and APHY-77

on page 81

for attaching cables

75 coaxial (RG-59B or equivalent) terminated with 75-ohm BNC
connectors

Maximum of 450 ft (137 m) of cable

APHY-82V

1 T-1 interface (UTP); see APHY-82V

on page 81

for attaching

cables

Note:

The APHY-82V is not a T1 interface. It merely allows you
to connect to a T1 CSU—the T1 CSU will allow you to
connect to a T1 circuit.

ITU-T G.703 for a symmetrical pair

100 ohm symmetrical pair

Maximum of 655 ft (200 m) of cable

0 through 6 dB loss at 200 m

APHY-67

PHY

APHY-77

PHY

APHY-82V

PHY

Advertising