5 connecting the receiver to the power supply, Connecting the receiver to the power supply, Table 5 – Ericsson ATSC Broadcast Receiver RX8320 User Manual

Page 9: Fuse type and rating, Warning

Advertising
background image

Installing the Equipment

)

Type of Connector

Description

ALARM

9-way male D-type connector for alarm signal output.

AC POWER

IEC100-120 V AC / 220-240 V AC power input.

TECHNICAL EARTH

Spade connector for unit technical earth.

2.5

Connecting the Receiver to the Power Supply

Warning!

Do not overload wall outlets and extension cords as this can result in a risk of fire or
electric shock.

As no mains switch is fitted to this unit, ensure the local power supply is switched
OFF before connecting the supply cord.

The receiver is not fitted with an on/off switch. Ensure that the socket-outlet is
installed near the equipment so that it is easily accessible. Failure to isolate the
equipment properly may cause a safety hazard.

Connect the receiver to the power supply as follows:

1. Ensure the power supply is isolated and switched off.

2. Ensure the correct fuse type and rating has been fitted to both the equipment

and the power cable.

3. Connect the lead to the receiver input connector and then to the power supply.

4. Switch on the power supply.

Table 5

Fuse Type and Rating

Power Supply

Fuse Type and Rating

100-120 V AC / 220-240 V AC

IEC/EN 60127-2 Sheet 5
Bussmann S505/Littelfuse 215
2 A 250 V T HBC

Note: Refer to the Reference Guide for all power supply, fuse replacement, safety,

EMC information and operating conditions.

EN/LZT 790 0008/2 R1A

2011-03-30

9 (36

Advertising