Maintenance and Cleaning

LED life: approx. 10,000 operating hours.
A new LED insert (ET-WCRL-LED) can be obtained
from the specified service address.

To do so, follow these steps:

Unscrew the tub mixer

10

from the fitting body

6

(see Fig. C1), which requires a cross-tip

screwdriver.

Unscrew the LED cover

9

from the fitting

body

6

using the socket head wrench

11

(see Fig. C2).

Remove the plastic LED insert (see Fig. C3–C4)

using the LED installation wrench

12

.

Install the new LED insert, the LED cover

9

and the tub mixer

10

to the fitting body

6

similar to disassembly (see Fig. C5–C7).

Replacing the screen

If the screen inside the LED cover is severely clogged
it must be cleaned or replaced.

To do so, follow these steps:

Unscrew the tub mixer

10

from the fitting body

6

(see Fig. C1), which requires a cross-tip

screwdriver.

Unscrew the LED cover

9

from the fitting body

6

using the socket head wrench

11

(see Fig. C2).

Push the screen out of the LED cover

9

from

the outside, using a flat object (see Fig. D1).

CAUTION RISK OF INJURY! The outer

edge of the screen fabric may be pointy.

Remove any limescale deposits or foreign bodies.

Replace the screen if severely clogged or dam-
aged. A new screen (ET-WCRL-WBS) can be
obtained from the specified service address.

Press the cleaned / new screen into the LED cover

9

from the inside (see Fig. D2).

Note: be sure the screen is properly seated in
the LED cover

9

.

Install the LED cover

9

and the tub mixer

10

in the fitting body

6

similar to disassembly

(see Fig. C6–C7).

Replacing the cartridge

A cartridge

13

is a wear part that needs replacing

according to the hardness and / or degree of con-
tamination of the water. This becomes evident
when the handle

16

becomes difficult to move. A

new cartridges

13

can be obtained from the listed

service office.
Note: this step requires an open-end spanner
SW 27 mm or fitting pliers.

Proceed as follows to replace the cartridge

13

:

Shut off the main water supply. Allow any

remaining water in the pipework to drain.

Remove the hot / cold plaque

18

by inserting a

flat object between the edge of the hot / cold
plaque

18

and the outside of the handle

16

.

Note: use light pressure to carefully push the
hot / cold plaque

18

outward so as not to

scratch the surface.

Loosen the locking screw

17

with the socket

head wrench

11

by turning it counter-clockwise.

CAUTION! Do not completely unscrew the
locking screw

17

. Only loosen this as far as is

necessary to remove the handle

16

.

Remove the handle

16

.

Unscrew the cartridge covering ring

15

, do not

use pliers or a spanner. Otherwise the product
could be damaged.

Loosen the cartridge locknut

14

below with

fitting pliers or an open-end spanner SW 27 mm
and remove the entire cartridge

13

from the

fitting body

6

.

Insert the new cartridge

13

(model 35 M LED)

into the fitting body

6

in the same manner.

Note: be sure the seal under the cartridge

13

is correctly seated. Make sure that the guides
are in the corresponding holes.

Reassemble all the above parts. Tighten the

cartridge lock nut

14

using fitting pliers or an

open-end spanner SW 27 mm while simultane-
ously securing the fitting from twisting. This will
achieve tightness and ensure the handle is not
difficult to move.

CAUTION! Be careful not to revere the hot/
cold water plaque

18

. The correct placement is: