Installation sheet, Page 4, Electrical – EdgeStar Model CW 2200 User Manual

Page 4: Water

Advertising
background image

Page 4

Installation sheet

Tools needed for Installation

Electrical

Refer to serial plate for specific
electrical requirements

Water

Washer dryer needs one standard 3/4 inch
water supply faucet with a pressure between
30 to 120 pounds per square inch

• Multi wrench
• Utility Knife
• Channel Lock
• Nut driver
• Level
• Screw driver

- Flat Blade

Parts supplied for installation.

Inlet Water Hose - One Washers - Two

Cabinet Dimensions

Height

33.46

inch

Depth

21.65

inch

Width 23.62 inch

Operation Of A Condensing Dryer

C

The washer dryer combo offers many
improvements in this method of drying. The

condensing chamber (b) is located outside of
the tub assembly, reducing the amount of heat
to overcome. This allows for more cooling of
the circulated air.

The air inside the unit is completely recycled and
never escapes the unit. This eliminates the need

for constantly heating cool outside air as is
necessary with traditional flow-through (vented)

dryers, resulting in reduced energy consumption.

In a properly designed “ventless” system it is
physically impossible for any air (steam) to escape
the unit because the intake of the fan must equal
the output. The only way air can be forced from
the unit is for additional outside air to be drawn
into the system, creating a positive pressure.

In a ventless system the cool air is passed over
the heater assembly and injected into the drum
creating steam within the unit. The hot, moist
air is then drawn from the drum of the unit and
passed through the condensing chamber where
it is subjected to the cooling effect of the

condensing spray, and the water is condensed
out of the air and collected.
(The effect is similar to having a glass of ice

water sitting on a table and condensation starts
to puddle). The air is then reheated and sent
back into the drum to absorb more moisture.
This cycle is repeated until all moisture is
removed from the air stream.

the baffle system of the condenser assembly at
a minimal rate. This cooling water is collected
along with the condensation and pumped out

sketch of the air flow through a ventless system.

During the drying cycle water is flowing through

of the system by the washer pump. Below is a

To Drain

a

e

b

d

c

Key:
a- Fan motor & heating assembly
b- Condensing chamber
c- Pump
d- Condensation and cooling water discharge
e- Cooling water inlet