Technical data, Risk of fire, Risk of personal injury – Tronic TSW 150 A1 User Manual

Page 35

Advertising
background image

- 33 -

Risk of fire!

• Do not use the device near hot surfaces.
• Do not locate the device in places exposed to

direct sunlight, Otherwise, it may overheat and
become irreparably damaged. Do not operate
the device in a vehicle that is standing out in the sun.

• Do not leave the device unattended when in use.
• Do not cover the fan's ventilation slots when the

device is switched on.

• Do not place any open sources of fire, like candles,

on the device.

• Due to high crossover resistances heating of the

plug in connector can result when using the ca-
bles with a 12 V vehicle plug.

Notice regarding disconnection from
the power supply

• This device's on/off switch does not completely

disconnect the device from the vehicle's power
and/or the battery. When the vehicle plug is
connected power is still supplied to the device.
To completely disconnect the device from the
vehicle power supply the 12 V vehicle plug must
be removed from the 12 V vehicle receptacle.

Risk of personal injury!

• Keep children away from the connecting cable

and the device. Children frequently underestimate
the dangers of electrical appliances.

• Do not operate the device if it has fallen or is

damaged. Have the device checked and repaired
if necessary by qualified technicians.

Technical data

DC Input

Voltage:

12 V

Maximum voltage:

15,5 V

Maximum power
consumption:

20 A

Low voltage alarm:

at 10,6 ± 0,3 V

Low voltage shutdown:

at 10 ± 0,3 V

Over voltage shutdown:

at 16 ± 0,5 V

AC Output

Voltage:

220-240 V ~ 50 Hz

Output power:

0,65 A

Continuous load:

150 W (> 4 h)/
170 W (30 min)

Peak load:

300 W (0,1 s)

Efficiency:

approx. 85 %

Output wave form:

modified sine

Overload protection:

200 W (+/- 10%)

Temperature Switch-off:

65°C
(at 50 W +/- 5%
Loading)

USB Port

Voltage: 5

V

Output current:

500 mA

Fusing

Cable fuse:

20 A Car-type fuse

General data

Measurements (without vehicle plug)
(L x B x H):

181 x 75 x 61 mm

Weight:

460 g approx.

Operating temperature:

5°...40°C

Operational humidity:

0 - 80 %
(relative humidity -
no condensation)

Subject to technical changes!

IB_70375_TSW150A1_GB_LB_ES.qxd 24.10.2011 12:46 Uhr Seite 33