Introduction & specification, Preparing drill for use 4. operating instructions – Sealey SA26 User Manual

Page 2

Advertising
background image

2.

INTRODUCTION & SPECIFICATION

3.1. Air Supply

WARNING! Ensure the air supply is clean and does not exceed 90psi while operating the drill. Too

high an air pressure and unclean air will cause excessive wear, and may be dangerous, causing

damage and/or personal injury.

3.1.1. Ensure the drill air valve (or trigger) is not depressed before connecting to the air supply.

3.1.2. You will require an air pressure between 70-90psi, and an air flow according to the specification above.

3.1.3. Drain the air tank daily. Water in the air line will damage the drill and invalidate your warranty.

3.1.4. Clean air inlet filter weekly. Recommended hook-up procedure is shown in fig 1.

3.1.5. Line pressure should be increased to compensate for unusually long air hoses (over 8 metres).

The minimum hose diameter should be 1/4” internal diameter and fittings must have compatible

dimensions.

3.1.6. Keep hose away from heat, oil and sharp edges. Check hoses for wear, and make certain that all

connections are secure.

3.2. Air Couplings

Vibration may cause failure if a quick change coupling is connected directly to the air drill. To

overcome this, connect a leader hose - Sealey model number AH2R - to the drill. A quick change

coupling may then be used to connect the leader hose to the air line hose. See fig.1 & fig.2.

3.

PREPARING DRILL FOR USE

4.

OPERATING INSTRUCTIONS

WARNING! Ensure you read, understand and apply safety instructions before use.

4.1. Fitting Drill Bit.

4.1.1.

Regularly check the drill bit and always change if worn, cracked or otherwise damaged.

WARNING! Disconnect drill from the air supply before placing drill bit into chuck.

4.1.2. Open or close the chuck jaws to a point where the opening is slightly larger than the drill or tool bit

(fig.3.A) to be used. Also raise the front of the drill slightly to prevent drill bit from falling out of the chuck

jaws. Insert the drill bit into the chuck as far as it will go. Place the chuck key in one of the chuck holes

and tighten the chuck securely.

WARNING! Ensure the chuck key is removed before starting the drill.

4.2. Connection to Air Supply.

Note! Squeeze the trigger to check that the drill is working correctly before starting work.

4.2.1.

DO NOT allow drill to run freely for an extended period of time as this will reduce bearing life.

4.3. Changing Direction of Rotation.

4.3.1. The change over button is located on the opposite side of the drill body from the trigger (fig.4).

4.3.2. To change the direction of rotation of the chuck, disconnect the drill from the air supply, push the change

over button inwards and rotate clockwise until it locks into place (fig.5).

Free Speed . . . . . . . . . . . . . . . . . . . 1500rpm

Operating Pressure . . . . . . . . . . . . . . . .90psi

Air Consumption . . . . . . . . . . . . . . . .13.5cfm

Air Inlet . . . . . . . . . . . . . . . . . . . . . . 1/4”BSP

Right angle air drill with 90° planetary gearbox. Ideal for drilling in hard to get at areas where normal drills will not fit.

Push-button reverse feature suitable for driving fixings. Supplied with 10mm chuck and key.

Weight . . . . . . . . . . . . . . . . . . . . . . . . . .1.1kg

Chuck Size . . . . . . . . . . . . . . . . . . . . .Ø10mm

Noise Power . . . . . . . . . . . . . . . . . .100.7dB.A

Noise Pressure. . . . . . . . . . . . . . . . .89.7dB.A

Original Language Version

SA26.V3 Issue: 1 - 09/07/12

© Jack Sealey Limited 2012