Fig.3, Applications chart, Part no: vs001.v3-p – Sealey VS0011 User Manual

Page 2

Advertising
background image

Alfa Romeo: . . . . . . . .VS001.V3-4

Audi: . . . . . . . . . . . . . .VS001.V3-2, 3, 4 or 7

BMW: . . . . . . . . . . . . .VS001.V3-4, 5 or VS0011.23

Chrysler: . . . . . . . . . . .VS001.V3-8, 7 or 10

Citroen:. . . . . . . . . . . .VS001.V3-7, 8 or 10

daewoo: . . . . . . . . . . .VS001.V3-2

Fiat:. . . . . . . . . . . . . . .VS001.V3-6 & 7

Ford: . . . . . . . . . . . . . .VS001.V3-2, 3, 16, 17, 18, 20 or VS0011.21

Honda: . . . . . . . . . . . .VS001.V3-7, 15 or 16

Hyundai: . . . . . . . . . . .VS001.V3-16

Kia: . . . . . . . . . . . . . . .VS001.V3-13

lancia: . . . . . . . . . . . .VS001.V3-7

Mazda: . . . . . . . . . . . .VS001.V3-16

Mercedes Benz: . . . . .VS001.V3-1, 8+10 or 9

Mitsubishi:. . . . . . . . . . .VS001.V3-8, 10+16

Nissan: . . . . . . . . . . . . .VS001.V3-8+10, 8+11+16

Peugeot: . . . . . . . . . . . .VS001.V3-6 or 7

Renault: . . . . . . . . . . . .VS001.V3-6 or 7

Rover:. . . . . . . . . . . . . .VS001.V3-5, 6 or 7

Saab: . . . . . . . . . . . . . .VS001.V3-2

Seat: . . . . . . . . . . . . . . .VS001.V3-3 or 4

Skoda: . . . . . . . . . . . . .VS001.V3-2 or 3

Suzuki: . . . . . . . . . . . . .VS001.V3-8+11+12 or 8+10 or 8+11

Toyota: . . . . . . . . . . . . .VS001.V3-8+11 or 15 or VS0011.25

Vauxhall/Opel: . . . . . . .VS001.V3-3, 6, 7, 16, VS0011.22 or 24

Volvo: . . . . . . . . . . . . . .VS001.V3-6 or 7

VW:. . . . . . . . . . . . . . . .VS001.V3-2, 3, 4 or 7

4. APPLICATIONS CHART

3.2.

CHECKING THE SYSTEM.

NOTE: Due to the design of the internal pump seal, a vigorous

pumping action is required to activate the seal and

pressurise the system. A light or slow pumping action

will prove ineffective. The larger the air space within the

cooling system being tested, the more vigorous the

initial pumping should be. By filling the cooling system

and therefore reducing the air space within, less effort

will be needed to pressurise it.

3.2.1. Pump the system until the pressure gauge (fig.3) indicates

approximately 15psi.

3.2.2. If gauge pointer remains stationary for one minute, it will

indicate that the cooling system is in good working order.

3.2.3. If the pointer falls it indicates that the system has a leak,

resulting in loss of pressure.

3.2.4. Check the system for water leaks and, if located, repair

accordingly.

3.2.5. If there is pressure loss but no external water leakage,

check the condition of the head gasket.

3.2.6. Re-test to ensure the repaired system is in good working

order.

Note! To release pressure from the pump, press the release valve

(fig.3). ensure the gauge is reading zero to indicate no

pressure, before disconnecting.

VS0011 Issue No.1 10/07/12

Original Language Version

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. edmunds, Suffolk,

IP32 7AR

01284 757500

01284 703534

[email protected]

www.sealey.co.uk

Web

email

PART No: VS001.V3-P

fig.3

Advertising