10. MAINTENANCE

10.1

GENERAL MAINTENANCE.

10.1.1 Ensure the machine is unplugged from the power supply. (1)

10.1.2 Disconnect the hose from the container. (2)

10.1.3 Undo the clasps and remove motor head from the container. (3)

10.1.4 Clear out any dirt or debris from the container and hose. (4)

10.1.5 Check that the telescopic suction tube operates smoothly,

and check the power cable to make sure it has not been

damaged.

10.2.

CARE OF CARTRIDGE FILTER

IMPORTANT! Clean or change the cartridge filter regularly

for best performance and long product life. The cartridge

filter is essential for the proper functioning of the cleaner.

If

the machine is used without a cartridge filter the motor

will burn out and the warranty will be voided. Always

keep a new, spare filter on hand.

10.2.1 The cartridge filters supplied are made of a high quality

material designed to trap small dust particles and should

only be used for dry vacuum cleaning.

If the cartridge filter

becomes wet it will clog very quickly and be very

difficult to clean. Always handle filters very carefully when

removing and cleaning them. Check the filter for tears or

small holes. Replace the filter if it is found to be damaged.

11. TROUBLESHOOTING

Symptom

Possible causes

Solutions

Vacuum will not operate

No power supply

Check power supply - cable, breakers, fuses.

Faulty power cable

Unplug and check the power cable. If

damaged have it replaced by your local Sealey

dealer.

Container full

Empty container

Dust expelled from the motor cover

Cartridge filter missing or damaged

Fit cartridge filter or replace damaged filter

Reduced efficiency and increased motor/

speed vibration

There is a blockage in the nozzle or hose

or in the container inlet.

Cartridge filter blocked by fine dust.

Check nozzle, hose and container inlets and clear

any blockages found.

Remove filter and clean it or install new filter.

12. CONSUMABLES

MODEL ..................................................................................................................................................................................PC300SDAUTO.V3

Locking Cartridge Filter (Must be used for dry vacuuming) ................................................................................................. Part No. PC200CFL

Foam Filter ......................................................................................................................................................................... Part No. PC200FF10

Dust Bags (Optional) ...........................................................................................................................................................Part No. PC300PB5

IMPORTANT! IF THE MACHINE IS USED WITHOUT A CARTRIDGE FILTER FITTED THE MOTOR WILL BURN OUT EVENTUALLY AND

YOUR GUARANTEE WILL BE INVALIDATED. ALWAYS KEEP A SPARE CARTRIDGE FILTER HANDY.

10.4

CLEANING CARTRIDGE FILTER

10.4.1 To remove the cartridge filter pull it carefully upwards and off

the filter cage. (C)

10.4.2 Clean the cartridge by gently tapping it over a waste

receptacle or lightly brushing with a soft brush. Do this

outdoors. (D)

10.4.3 If a cartridge filter becomes inadvertently wetted it should be

removed and allowed to air dry for 24 hours before reinstalling.

10.5

FITTING A FOAM SLEEVE FILTER (WET VACUUM ONLY)

10.5.1 Remove the power head and turn it upside down. Carefully

remove the cartridge filter and store safely for future use.

10.5.2 Slide the foam sleeve filter down over the filter cage ensuring

that the whole cage is covered. See 1`& 2

10.5.3 Invert the power head and refit it onto the container

10.6

CLEANING A FOAM SLEEVE FILTER

10.6.1 Carefully remove the foam sleeve from the filter cage.(3)

10.6.2 Wash the foam sleeve in a mild soap and water solution and

then rinse it in clean water. (4)

10.6.3 Allow the filter to air dry before installing and using again.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

10.3

INSTALLING CARTRIDGE FILTER (DRY VACUUM ONLY)

10.3.1 Remove the top section and with the raised rim uppermost fit

the cartridge filter tube down over the filter basket and push

fully home. Place the locking disc onto the top of the filter

and turn the locking bar until the latch drops into the slot in

the top of the filter cage. Continue turning until the filter is

fully locked down. (see below)

9.1

Connect the tool to the vacuum hose using the rubber adaptor

supplied. Ensure that the ON/OFF switch is in the

OFF

position then plug the dust free tool into the covered socket

provided on the front of the power head (see fig.1-12). Move

the function switch to the double bar position. Move the ON/

OFF switch to the ON ('I') position. The vacuum cleaner will

start automatically when the tool is switched on. When the

tool is switched off the vacuum will continue to run for 10

seconds to ensure that the tool and hose are left free of dust.

9. USING DUST FREE TOOLS