5.7 Recommended oils

Recommended oil for compressors,

suitable for room temperatures

ranging from 5°C to 25°C: SEALEY

CPO compressor oil.

Room temperature below 5°C: SAE

20 compressor oil.

Approximate oil capacity: 0.16 litres.

5.8. IMPORTANT WARNING -

Air contaminants taken into the

compressor will affect optimum

performance.

Example: Body filler dust or paint

overspray will clog the pump intake

filter and may cause internal

damage to pump/motor components.

Please note that any parts damaged

by any type of contamination will not

be covered by warranty.

WARNING! Never mix different oils and do not use non-detergent/low quality oils as the compressor may be damaged.

WARNING! Dispose of waste oil only in accordance with local authority requirements.

5.5.

Operations to be carried out every 400 hours:

a)

Replace air filter. (See figs.8 or 9 depending on model.)

b)

Check all tube fittings and electrical connections.

6. TROUBLE SHOOTING

Fault

Cause

Remedy

Pressure drop in the tank.

Air leaks at connections.

Run compressor to max. pressure, switch off.

Brush soap solution over connections and look for

bubbles. Tighten connections showing leaks.

If problem persists contact Authorised Service Agent.

Pressure switch valve leaks when compressor is idle. Non-return valve seal defective.

Replace pressure switch.

Compressor stops and does not restart.

Power failure.

Motor failure.

Check electricity supply and fuse.

Contact Authorised Service Agent.

Compressor does not stop at max pressure.

Pressure switch fault.

Contact Authorised Service Agent.

Compressor does not reach max pressure.

Filter clogged.

Head gasket or valve fault.

Replace filter element.

Contact Authorised Service Agent.

Compressor noisy with metallic knock.

Low oil level.

Bearing or piston damage.

Turn off and top up oil immediately.

Contact Authorised Service Agent.

5.6. Maintenance Schedule

noTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

MAINTENANCE OPERATIONS

Weekly 50hrs 100hrs 3 Months

Drain condensation

Check oil level

Clean intake filter

Check for oil leaks

Replace oil

Check cut-out

General cleaning of compressor

Replace air filter

Check tube fittings and electrical connections

SA5020

SA5025

SA2415, SA2420, SA5020, SA5025 Issue: 5 - 21/05/12

5.9

Inspection of pressure tank both inside and out.

Under the PRESSURE SYSTEMS SAFETY REGULATIONS 2000 it is the responsibility of the owner of the compressor to initiate a system

of inspection that both defines the frequency of the inspection and appoints a person who has specific responsibility for carrying out the

inspection.