background image

6. TROUBLE SHOOTING

5.7. Scheduled maintenance table

Internal & external

inspection of tank

General cleaning of

compressor

Check tube fittings and

electrical connections

Check for oil leaks

Replace air filter

Clean intake filter

Check oil level

Drain condensation

400 hrs.

200 hrs.

100 hrs.

Daily

Maintenance

Operations

Replace oil

Check cut-out

Fault

Cause

Remedy

Pressure drop in the tank.

Air leaks at connections.

Run compressor to max. pressure, switch off unit.

Brush soap solution over connections and look for

bubbles. Tighten connections showing leaks.

If problem persists contact Authorised Service Agent.

Pressure switch valve leaks when compressor is idle.

Non-return valve seal defective.

Empty the air tank, remove the non-return valve cap

(fig.5.3) and clean, or if necessary, replace

the seal (fig.5.1).

Compressor stops and does not restart.

Motor failure.

Contact Authorised Service Agent.

Compressor does not stop at max. pressure.

Pressure switch fault.

Contact Authorised Service Agent.

Filter clogged.

Head gasket or valve fault.

Clean or replace filter element.

Contact Authorised Service Agent.

Compressor noisy with metallic knock.

Bearing or piston damage.

Contact Authorised Service Agent.

Overload switch activated (Fig.6).

Leave for a few minutes then press the reset button.

Remove extension lead and test the compressor by

connecting as near to the main fuse box as possible.

Extension lead too long.

Head unloader not operating (Section 4.3.5).

Contact Authorised Service Agent.

Occasionally the start up load may activate switch.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

SAC10030.V2, SAC05030.V2 Issue: 1 - 14/05/13

fig.5

fig.6

5.8. IMPORTANT WARNING - Air contaminants taken into the

compressor will affect optimum performance. Example: Body

filler dust or paint overspray will clog the pump intake filter and

may cause internal damage to pump/motor components. Please

note that any parts damaged by any type of contamination will

not be covered by warranty.