background image

Maintenance

Operations.

Weekly.

Daily.

Monthly.

200 hrs.

drain condensation.

check oil level.

check guards/covers.

check for oil leaks.

Replace air filter.

check fittings.

Inspect Pressure Tank.

change pump oil.

check belt tension.

clean air filter.

check safety relief valve.

clean compressor.

check for air leaks.

check for noise or

vibration.

5.3. SCHEDULED MAINTENANCE TABLE (NOT ENGINE)

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: no liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

SA1565 Issue: 2 - 20/02/12

Environmental Protection.

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be

sorted, taken to a recycle centre and disposed of in a manner which is compatible with the environment.

When the product is no longer required, it must be disposed of in an environmentally protective way.

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk,

email [email protected] or phone 01284 757500.

5.4. Recommended oils

Synthetic oil suitable for temperatures ranging from -5°c to

45°c: viscosity 5W50. We

DO NOT recommend using mineral

oil in this compressor.

Part no. Qty. description

FSO1

1ltr x 12 compressor oil fully synthetic

FSO1S 1ltr x 1 compressor oil fully synthetic

FSO5

5ltr x 1 compressor oil fully synthetic

5.5. IMPORTANT WARNING - Air contaminants taken into the

compressor will affect optimum performance. Example: Body

filler dust or paint overspray will clog the pump intake filter and

may cause internal damage to pump/motor components.

Please note that any parts damaged by any type of

contamination will not be covered by warranty.

6. TROUBLE SHOOTING

Fault

Cause

Remedy

Pressure drop in the

tank.

Air leaks at

connections.

Run compressor to max.

pressure, switch off.

Brush soap solution over

connections and look for

bubbles. Tighten connections

showing leaks. If problem

persists contact Authorised

Service Agent.

Pressure switch

valve leaks when

compressor is idle.

non-return valve seal

defective.

discharge all tank pressure.

contact Authorised Service

Agent.

compressor stops

and does not restart.

Power failure.

Motor failure.

check electricity supply and

fuse.

contact Authorised Service

Agent.

compressor does

not stop at max

pressure.

Pressure switch fault. contact Authorised Service

Agent.

compressor does

not reach max

pressure.

Filter clogged.

Head gasket or valve

fault.

Replace filter element.

contact Authorised Service

Agent.

compressor noisy

with metallic knock.

low oil level.

Bearing or piston

damage.

Turn off and top up oil

immediately.

contact Authorised Service

Agent.