Sealey SSQC0903P User Manual

Super quiet compressors, Instruction manual for, Model no's

Advertising
background image

InstructIon manual for:

SUPER QUIET

COMPRESSORS

thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions and

properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.2.

GENERAL SAFETY INSTRUCTIONS

3

familiarise yourself with the application and limitations of the compressor.

3

Ensure that the compressor is in good order and condition before use. If in any doubt do not use. contact an electrician/service agent.

WARNING!

the compressor must be serviced by an authorised agent only. DO NOT tamper with, or attempt to adjust, the

pressure switch or the safety valve.

3

Before moving, or maintaining the compressor ensure that it is unplugged from the mains supply and that the air tank pressure has been

vented.
3

only use recommended parts and accessories. to use unauthorised items may be dangerous and will invalidate your warranty.

3

read the instructions regarding any accessory used with the compressor. Ensure that the safe working pressure of any air appliance used

exceeds the output pressure of the compressor.

3

Ensure that the air supply valve is turned off before disconnecting the air supply hose.

3

Keep tools and other items away from the compressor when it is in use and keep the area clean and free of unrelated items.

3

Ensure that the air hose is not tangled, twisted or pinched.

3

Keep children and unauthorised persons away from the work area.

7

DO NOT dis-assemble compressor for any reason. the unit must be checked by qualified personnel only.

7

DO NOT use the compressor outdoors, or in damp, or wet, locations and DO NOT operate it within the vicinity of flammable liquids, gases

or solids.

7

DO NOT touch compressor cylinder, cylinder head or pipe from head to tank as will be hot and will remain so for some time after shutdown.

7

DO NOT attempt to move the compressor by pulling the air supply hose. only move the compressor by the handle.

7

DO NOT attempt to lift or move the compressor by any means other than by the handle.

1.1. ELECTRICAL SAFETY

WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. a

residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also recommend that a residual current

Device (rcD) is used. It is particularly important to use an rcD with portable products that are plugged into a supply which is not protected

by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current Device by contacting your sealey dealer.

You must also read and understand the following instructions concerning electrical safety.

1.1.1. the

Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified

electrician, using a Portable appliance tester (Pat), at least once a year.

1.1.2. the

Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances

and the safety of the appliance operators.

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.

and use a Portable appliance tester.

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. regularly inspect power supply cables and plugs for wear or damage and check all

connections to ensure that none is loose.

1.1.6.

Important: Ensure that the voltage marked on the appliance matches the power supply to be

used and that the plug is fitted with the correct fuse - see recommended fuse rating at right.

1.1.7.

DO NOT pull or carry the appliance by the power cable.

1.1.8.

DO NOT pull the plug from the socket by the cable.

1.1.9.

DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty

item repaired or replaced by a qualified electrician. When an asta/Bs approved uK

3 pin plug is damaged, cut the cable just above the plug and

dispose of the plug safely.

fit a new plug according to the following instructions (uK only).

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to the live terminal ‘L’.

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer

insulation extends beyond the cable restraint and that the restraint is tight.

Double insulated products, which are always marked with this symbol , are fitted with live (brown) and neutral (blue) wires only.

to rewire, connect the wires as indicated above -

DO NOT connect either wire to the earth terminal.

1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure

that a 30 amp supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your

electrician.

1.1.11. If an extension reel is used it should be fully unwound before connection. a reel with an rcD fitted is preferred since any appliance

plugged into it will be protected. the section of the cores in the cable is important and should be at least 1.5mm², but to be absolutely

sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we

recommend the use of 2.5mm² section cable.

1. SAFETY INSTRUCTIONS

Original Language Version

moDEl no's

SSQC0903P

SSQC2405P

SSQC2409

RECOMMENDED FUSE RATING:

13 AMP

ssQc0903P, ssQc2405P, ssQc2409 Issue: 3 (sP) - 22/07/13

© Jack sealey limited

Advertising
This manual is related to the following products: