Troubleshooting fault cause remedy – Sealey SSQC0903P User Manual

Page 5

Advertising
background image

7. TROUBLESHOOTING

FAULT

CAUSE

REMEDY

1a) Pressure drop in the tank

air leaks at connections

run compressor to max. pressure, switch off.

Brush soap solution over connections and look for

bubbles. tighten connections showing leaks.

If problem persists contact authorised service

agent.

1B)

Pressure drop in the tank

air leaks from safety valve

operate the safety valve manually by pulling on the

ring. If valve continues to leak when in the closed

position it should be replaced.

1c) Pressure drop in the tank

air leaks from cylinder head gasket

check tightness of head bolts. If leak continues

contact authorised service agent.

2) Pressure switch valve leaks when
compressor is idle

non-return valve seal defective

Empty the air tank, remove the non-return valve

cap and clean, or if necessary replace the seal.

3) air leaks from tank body or tank welds

Internal corrosion caused by infrequent tank

draining or non permitted modifications to tank

tank could rupture or explode. cannot be repaired.

DISCONTINUE USE IMMEDIATELY.

4a) motor stops and will not restart

thermal cut out has operated

allow unit to cool for 30 minutes before restarting

4B) motor stops and will not restart

supply fuse has tripped

reset fuse and restart unit. If repeated tripping

occurs replace the check valve or contact

authorised service agent.

4c) motor stops and will not restart

current overload trip has operated

remove from main supply and Investigate and

remedy reason for overload.

5) compressor stops and does not restart

motor failure

contact authorised service agent.

6a) compressor does not stop at max. pressure

Pressure switch fault

contact authorised service agent.

6B) compressor does not stop at max. pressure

filter clogged

Head gasket or valve fault

replace filter element.

contact authorised service agent.

7) compressor noisy with metallic knock

Bearing or piston damage

contact authorised service agent.

8) Excessive moisture in discharged air

High humidity environment

Drain tank after each use.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: no liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, suffolk Business Park

,

Bury st. Edmunds, suffolk,

IP32 7ar

www.sealey.co.uk

W e b

email

Original Language Version

ssQc0903P, ssQc2405P, ssQc2409 Issue: 3 (sP) - 22/07/13

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk,

email [email protected] or phone 01284 757500.

© Jack sealey limited

Advertising
This manual is related to the following products: