5. mAINTeNANCe

5.1

Changing the Digital Meter Battery

5.1.1 Remove the rubber protective cover from the meter.

5.1.2 Remove the screw and cover from the side of the meter.

5.1.3 Remove and replace battery (fig.7).

5.1.4 Replace cover and secure with screw.

5.1.5 Replace the protective rubber cover.

Note: If the LcD display does not activate, remove the meter as in section 4.5.1, press

button 1 (fig.6.1) to reboot the meter.

5.2

Before every use visually check the supply hose for damage and check all joints

for leaks, any damaged component must be replaced or leaks repaired before

using.

5.3

check the nozzle valve for leaks, if it does not seal, replace before using.

5.4

Drain air regulator water trap daily.

5.5

top up lubricator as required, using a quality air tool oil.

5.6

To change the silencer, remove the circlip (fig.8) and remove the old silencer,

place a new silencer into the recess and refit the circlip.

Note: For any other maintenance and repairs the unit should be returned to your

Sealey dealer.

fig.8

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

ImpORTANT: no liability is accepted for incorrect use of product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORmATION: call us for a copy of our latest catalogue on 01284 757525 and leave your full name and address including your postcode.

01284 757500

[email protected]

www.sealey.co.uk

01284 703534

Sole U.K. Distributor

Sealey Group

Bury St. Edmunds

Suffolk.

Web

6. DeClARATION OF CONFORmITY

the construction file for this product is held by the Manufacturer and may be inspected on

request by contacting Jack Sealey Ltd.

For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.

Oil Dispensing Pump Station

Air Operated

Model: AK4560D

2002/95/Ec RoHS Directive

2002/96/EEc WEEE Directive

5th november 2008

Signed by Steve Buckle

4.6

Changing the Units

Note: the meter is pre-set to display litres.

4.6.1 Press button "2" on the rear of the meter for 1 sec to enter the correction Factor

mode.

4.6.2 Press the Move button five times to select the units (fig.4.3).

4.6.3 Press the Reset button to scroll through the Units (L/Gal/Pt/Qt), select the Unit

required.

4.6.4 Press "2" for 1 sec to quit the correction Factor mode.

fig.5