4. MAINTENANCE

WARNING! With the exceptions listed below, all pump and electrical cable service maintenance and repair must be

undertaken by an authorised service agent only. Failure to observe this rule may be dangerous and will invalidate your warranty.

WARNING! Ensure that the pump is disconnected from the mains power supply before attempting any service or maintenance.

4.1.

Cleaning the filter sponge.

4.1.1. Press the filter housing together on both sides, turn anticlockwise (fig.3) and pull off the cover.

4.1.2. Remove the sponge filter (fig.3) from the housing and clean with clean cold water.

Caution: never use the pump without the filter in place as this could lead to damage to the pump.

4.2.

Cleaning the functioning parts.

4.2.1. Open the pump chamber lid (fig.4) by twisting it anticlockwise and pulling it clear of the pump body. Remove the washer from the

bottom of the shaft.

4.2.2. Remove the magnetic impeller (fig.5) carefully from the shaft. As this is done the magnetic force of the impeller must be overcome.

There is a washer on the top end of the impeller shaft.

4.2.3. Do not use any implements to remove dirt from inside the pump, but simply wash it out with lukewarm water.

4.2.4. Use a soft sponge to remove any dirt deposits.

4.2.5. To reassemble the pump, check that the washer is fitted on the top end of the shaft, carefully slide the magnetic impeller onto the

shaft. At a certain point, the impeller will be drawn into the housing by the magnetic force.

4.2.6. Check that the rubber bearing (fig.5), at the end of the shaft, is correctly mounted.

4.2.7. Before closing the pump chamber with the lid make sure that its o-ring is correctly seated.

4.2.8. Plug the supply cable into the mains supply briefly (no more than 3 seconds) to check that the impeller turns freely. A certain level of

noise is inevitable during this dry run, this is no cause for concern. When it is used in water, the pump should operate silently.

4.3.

Winter storage

4.3.1. Place the pump in water filled vessel in a frost free room. Storage in water prevents deposits from accumulating on the pump. If the

pump is stored dry, these deposits can block the impeller. If you wish to store the pump dry, you must ensure that the functioning

parts and filters have been thoroughly cleaned and dried.

4.3.2.

DO NOT operate pump in temperatures of below 5°C.

noTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

W e b

email

Original Language Version

WPP1750S, WPP3000S, WPP3600S Issue: 1 - 19/11/13

© Jack Sealey Limited

fig. 3

fig. 4

fig. 5

Environmental Protection.

Recycle unwanted materials instead of disposing of them as

waste. All tools, accessories and packaging should be sorted,

taken to a recycle centre and disposed of in a manner which

is compatible with the environment.

WEEE Regulations.

Dispose of this product at the end of its working life in compliance

with the EU Directive on Waste Electrical and Electronic Equipment.

When the product is no longer required, it must be disposed of in an

environmentally protective way. Contact your local solid waste

authority for recycling information.

Parts support is available for this product. To obtain a parts listing and/or diagram,

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.

Advertising
This manual is related to the following products: