Fp o n, En g li sh – Everpure H-300 User Manual

Page 4

Advertising
background image

EN

G

LI

SH

• 4 •

MOUNT FILTER HEAD UNDER SINk

Identify Filter Head and the two Elbow Fittings, and

note that the Outlet Fitting has a black band. This fitting

includes a small restrictor insert to insure maximum

flow at 1/2 gallon per minute.

Apply Teflon Tape to the threads of each Elbow Fitting.

Wrap tape in direction of the threads to assure a tight fit

and avoid small leaks.

Screw Inlet Elbow Fitting into the left side of the filter

head, and hand tighten only.

Screw Outlet Elbow Fitting (black band) into the right

side of the filter head in the same manner.

Securely mount the filter head on the cabinet wall using

the enclosed mounting screws and washers.

ATTACH INLET wATER SUPPLy

Locate and close the cold water Angle Stop Valve under

your kitchen sink. Open cold water line of faucet to

release water pressure.

Unscrew and disconnect the braided tubing on top of the

Angle Stop Valve .

Attach the bottom of Angle Stop Adaptor to the existing

cold water Angle Stop Valve.

Attach the braided tubing to the top of the Angle Stop

Adaptor.

Close side valve on Angle Stop Adaptor and open cold

water Angle Stop Valve to return water service to

kitchen sink. Check for leaks.
NOTE: Teflon

®

Tape should not be required for these

next steps.

Measure length of tubing needed to connect Angle

Stop Adaptor to Inlet Elbow Fitting on Filter Head. Allow

adequate tubing to avoid sharp turns.

Cut tubing at a 90° angle using a sharp knife.

Insert ends of tubing into quick-connect fittings. Push

tube into fitting and gently pull to confirm a tight fit.

ATTACH FILTERED wATER TO SINk FAUCET

Install separate faucet for filtered drinking water. Follow

individual manufacturer’s instructions.

Attach Faucet Connector Fitting to bottom end of

threads on new faucet assembly. Teflon

®

Tape should

not be required for this step.

Measure length of tubing needed to connect the

Outlet Elbow Fitting on Filter Head to the new Faucet

Connector Fitting. Allow adequate tubing to avoid sharp

turns. Cut and insert each end of the tubing into the

fittings.

OPTIONAL FILTER MONITOR (H300+M Filter System)
A Filter Replacement Monitor (EV3112-01) is included with the

H300+M Filter System. It is a small water meter that counts the

number of gallons used. This Monitor includes quick-connect

fittings, and should be installed on the tubing between the filter

system and the faucet connector.
Monitor Instructions (Document EV3112-52) are included with

the H 300+M System.

3.

A.

B.

C.

D.

E.

1.

F.

G.

H.

I.

J.

K.

L.

M.

5.

N.

O.

P.

3

B

C

D

E

G

H

I

L

M

4

F

P

O

N

5

Advertising