How to order repair parts, Troubleshooting, Symptoms - possible causes and correction s – Empire Comfort Systems VFYR-24SO-1 User Manual

Page 20

Advertising
background image

Page 20

12409-2-0403

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or

pressure is low, contact your local gas supplier immediately.

1. When ignitor button is pressed, there is no spark at ODS/

pilot.
a. Ignitor electrode positioned wrong - Replace pilot.
b. Ignitor electrode is broken - Replace pilot.
c. Ignitor electrode not connected to ignitor cable - Reconnect

ignitor cable.

d. Ignitor cable pinched or wet. Keep ignitor cable dry - Free

ignitor cable if pinched by any metal or tubing.

e. Broken ignitor cable - Replace ignitor cable.
f. Bad piezo ignitor - Replace piezo ignitor.

2. Appliance produces unwanted odors.

a. Appliance burning vapors from paint, hair spray, glues, etc.

- Ventilate room. Stop using odor causing products while
heater is running.

b. Gas leak - Locate and correct all leaks.

3. Appliance shuts off during use. (Pilot and main burner are

off.)
a. Not enough fresh air is available for ODS/pilot to operate -

Open window and/or door for ventilation.

b. Low line pressure - Contact local gas company.
c. ODS/pilot is partially clogged - Clean ODS/pilot.
d. Defective thermocouple - Replace pilot.

4. Appliance shuts off during use. (Pilot stays on.)

a. Low line pressure - Check line pressure to the valve.
b. Defective thermopile - Check pilot flame, check wire con-

nections, output should be a minimum of 325 millivolts
across. TH/TP and TP terminals with ON/OFF switch off.

5. Gas odor even when control knob is in OFF position.

a. Gas leak - Locate and correct all leaks.
b. Control valve defective - Replace control valve.

6. When ignitor button is pressed, there is spark at ODS/pilot,

but no ignition.
a. Gas supply turned off or manual shutoff valve closed - Turn

on gas supply or open manual shutoff valve.

b. Control knob not in PILOT position - Turn control knob to

PILOT position.

c. Control knob not pressed in while in PILOT position - Press

in control knob while in PILOT position.

d. Air in gas lines when installed - Continue holding down

control knob. Repeat igniting operation until air is removed.

e. ODS/pilot is clogged - Replace ODS/pilot assembly or get it

serviced.

g. Gas regulator setting is not correct - Replace gas regulator.

7. ODS/pilot lights but flame goes out when control knob is

released.
a. Control knob not fully pressed in - Press in control knob

fully.

b. Control knob not pressed in long enough - After ODS/pilot

lights, keep control knob pressed in 30 seconds.

c. Manual Shutoff valve not fully open - Fully open manual

shutoff valve.

d. Thermocouple connection loose at control valve - Hand

tighten until snug, then tighten 1/4 turn more.

e. Pilot flame not touching thermocouple, which allows ther-

mocouple to cool, causing pilot flame to go out. This prob-
lem could be caused by either low gas pressure or dirty or
partially clogged ODS/pilot - Contact local gas company.

f. Thermocouple damaged - Replace thermocouple.
h. Control valve damaged - Replace control valve.

8. Burner does not light after ODS/pilot is lit.

a. Burner orifice clogged - Clean burner or replace main burner

orifice.

b. Burner orifice diameter is too small - Replace burner orifice.
c. Inlet gas pressure is too low - Contact qualified service

person.

9. Burner backfires during combustion.

a. Manifold pressure is too low - Contact local gas company.
b. Burner orifice clogged - Clean burner or replace burner

orifice.

10. Logs appear to smoke after initial operation.

a. Vapors from paint or curing process of logs - Problem will

stop after a few hours of operation. Run the heater with the
damper open if you have one, or open a window for the first
few hours.
Log heater is intended to be smokeless. Turn OFF heater and
call qualified service person.

11. Heater produces a whistling noise when main burner is lit.

a. Turning control knob to HIGH position when main burner is

cold - Turn control knob to LOW position and let warm up
for a minute.

b. Air in gas line - Operate burner until air is removed from

line. Have gas line checked by local gas company.

c. Dirty or partially clogged burner orifice - Clean burner or

replace burner orifice.

12. No gas to pilot.

a. LP-regulator shut down due to inlet pressure too high -

Verify LP tank regulator is installed and set at 11" to 13" w.c.
Replace regulator on heater.

TROUBLESHOOTING

SYMPTOMS - POSSIBLE CAUSES AND CORRECTION

S

Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater.

Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor.
Parts can be shipped directly to the service person/dealer.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your equipment. Then
determine the Part Number (not the Index Number) and the Description of each part from the following appropriate illustration and list. Be sure to give
all this information . . .

Applaince Model Number

Part Description

Appliance Serial Number

Part Number

Type of Gas (Propane or Natural)

Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.

Shipments contingent upon strikes, fires and all causes beyond our control.

Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62220-2623