Connecting the PSM Cables and AC Power Cords

2-6 Installation

Connecting the PSM Cables and AC

 

Power Cords

The PSMs are connected to the SecureStack C2 Ethernet switch devices using C2RPS‐PSM 
Cables. 

To connect the PSMs, proceed as follows:

1.

Connect one end of the C2RPS‐PSM Cable (shown in 

Figure 2‐3

) to the Redundant 

Power Supply connector on the switch device. Then connect the other end to the 
Redundant Power Supply connector at the rear of the PSM as shown in 

Figure 2‐4

 and 

Figure 2‐5

.

2.

Connect a standard AC power cord to the AC input power connector on the PSM 
shown in 

Figure 2‐4

, then plug the AC power cord into the main AC power outlet. 

3.

The green Power LED on the front of the PSM will illuminate to indicate a successful 
connection. If the LED remains off, proceed as follows:

a.

Check the AC power cord connection at the AC power source and make sure the 
power source is within specification.

b. Check the AC power connection to the PSM.

c.

Swap the AC power cord with a known good one.

d. If the green LED continues to remain off, contact Enterasys Networks. Refer to 

Getting Help

” on page 1‐5 for instructions. Otherwise, proceed to step 4.

4.

If installing two PSM power supplies, repeat steps 1 through 3 for the second PSM.

Figure 2-3 C2RPS-PSM Cable

Figure 2-4 Power Connectors on C2RPS-PSM (rear view)

1 Redundant Power Supply connector

2 AC power connector (rear of chassis)

AC LINE

100-240 VAC

50-60 Hz

2A MAX

Redundant Power Supply

А

Б