Resistance measurement, Continuity test – Powerfix PDM 250 A1 User Manual

Page 15

Advertising
background image

POWERFIX PDM 250 A1

English - 13

Resistance measurement

Ensure that all circuit elements, circuits and components to be measured and other test

objects are completely switched off and discharged. Otherwise, the multimeter could be

damaged.

 Connect the black test lead to the COM jack [5] and the red test lead to the V/Ω jack [6].

 Set the range selector switch [4] to the desired range in the Ω measuring range.

 Connect the test probes [7] to the test object.

 The measurement result is then indicated on the display [1].

For resistances > 1MΩ, the measurement may take a few seconds. In this case, wait until the

measured value has stabilised.

The test probes [7] should be handled only behind the finger protection to avoid a distorted

measurement result.

For measurements of low resistances (200Ω range), the internal resistance of the test leads

can lead to a distorted result. To avoid such an error, note the value of the measurement for

short-circuited test probes and deduct this from the value of the actual measurement.

Continuity test

Ensure that all circuit elements, circuits and components to be measured and other test

objects are completely switched off and discharged. Otherwise, the multimeter could be

damaged.

 Connect the black test lead to the COM jack [5] and the red test lead to the V/Ω jack [6].

 Set the range selector switch [4] to the

position in the Ω measuring range.

 Connect the test probes [7] to the test object.

 If the resistance is less than approximately

60Ω, the buzzer sounds and the measurement

result is indicated on the display [1].