English - 7

Resistance

Range Resolution

Precision

200Ω 0.1Ω ±

(1.0%+5)

2kΩ 1Ω

± (0.8%+3)

20kΩ 10Ω

200kΩ 0.1kΩ

2MΩ 1kΩ

20MΩ 10kΩ ±

(1.2%+3)

Overload protection: 250V

Battery test

Range Consumption

1.5V ±20mA

9V ±5mA

The specified precision in ± (% of the display + number of digits) is guaranteed for a period of
one year at an ambient temperature from 18°C to 28°C and maximum air humidity of 75%.

Safety instructions

Before using this multimeter for the first time, always read the following instructions and pay

attention to all warnings, even if you are familiar with handling electronic devices. Store these

instructions in a safe place for future reference. If you sell the multimeter or pass it on, always

include these instructions.

This symbol indicates important information for safe operation of the

multimeter and the safety of the user.

This symbol indicates other important information on the topic.