Troubleshooting – Powerfix Z22855 User Manual

Page 38

Advertising
background image

gB/MT

38

to obtain the zero position (ZERO)

9

.

j

Now measure the entire object. The LCD display

5

now

shows the thickness of the floor of the object.

Measuring the distance between two identical
holes (see fig. F):

j

First measure one of the two, equally sized holes.

j

Leave the measuring jaws

2

/

11

in this position and press

the key to obtain the zero position (ZERO)

9

.

j

Now measure the total dimension. The LCD display

5

now

shows the average distance.

Characteristics of metric ISO screw threads:

Nominal diameter:

[mm]

Increase:

[mm

-1

]

Core diameter:

[mm]

Drill

diameter:

[mm]

3

0.5

2.46

2.5

4

0.7

3.24

3.3

5

0.8

4.13

4.2

6

1

4.92

5

8

1.25

6.65

6.8

10

1.5

8.38

8.5

12

1.75

10.11

10.2

16

2

13.84

14

20

2.5

17.29

17.5

Q

Troubleshooting

The device contains sensitive electronic components. That is why
it experiences interference when in close proximity to radio
transmission devices. If any indication errors appear in the
display, remove such devices out of the proximity of the calliper.
Electrostatic discharge could result in malfunctions.

j

When such malfunctions occur, remove the battery for a
short while and re-insert.

Failure

Cause

Solution

Five digits flash

simultaneously

every second.

The battery voltage

is lower than 2.75 V.

Replace the battery

in line with the chap-

ter on “Inserting /

replacing battery”.

The LCD dis-

play

5

does

not continue to

count.

Faulty wiring or

circuit

Remove battery

and re-insert after

30 seconds.

Advertising