Cooler Installation

Install Casters

This unit comes equipped with 4 stem casters; 2 locking and 2 non-locking. Before operation turn the unit
on its side and press the stem casters into the corner holes. Install the locking caster on one side of the
unit and the non-locking casters on the opposite side.

Operation

Fill With Water

To fi ll this unit with water, open the water access door and fi ll with a pitcher or
water hose (see fi g. 1). Do Not Overfi ll.

Water Level Indicator

On the front of the unit there is an access window to view the water level indica-
tor (see fi g. 2). When the unit is full of water, the level indicator will show
mostly blue. As the level of the water is decreased in the unit, the blue on the
indicator will diminish.

Power On Unit

Refer to the control panel in fi gure 3 for the following instructions.
Once the unit is plugged in, pressing the “Power” button will light up the back-
light on the display and start the unit in Fan-High mode. The pump will not start until the “Pump” button
is pressed. The display will remain backlit for 2 minutes after the last button
on the control is pushed.

Pump / Cooler Operation

To operate this unit as an evaporative cooler, the unit must be fi lled with wa-
ter and the pump powered on. Press the “Pump” button to turn on the pump.
The water drop indicator on the display will fl ash while the pump is on. To
operate the unit as a fan only, press “Pump” to turn off the pump.

Note: The pump will not run if the water level falls below a certain level.
When the water level drops below this level, an audible alarm will sound
and the “Low Water” indicator on the display will fl ash on and off. The au-
dible alarm will stop after 60 seconds or when the “Pump” button is pushed.
The indicator will remain fl ashing until the unit is fi lled with water. You
will need to restart the pump by pressing “Pump” after the unit is refi lled
with water.

Fan Operation

Pressing the “Speed” button on the control will cycle the fan
speed from High to Mid to Low. The speed setting will be
highlighted in the display.

Oscillate Mode

Pressing the “Oscillate” button will oscillate the vertical vanes
back and forth. The oscillate indicator on the display will be
displayed when on. Press the button again to turn off.

Timer Mode

This unit is equipped with a timer. You may set the time interval for the unit to stay on. Pressing the
“Timer” button will set the time interval in 1/2 hour increments up to 8 hours. The display will fl ash while
setting the time and will be solid once it is set. The display will count down the time remaining in 1/2
hour increments. When the time interval is reached, the unit will turn off.