Limited Warranty

This warranty is extended to the original purchaser of an evaporative cooler installed and used under nor-
mal conditions. It does not cover damages incurred through accident, neglect, or abuse by the owner. We
do not authorize any person or representative to assume for us any other or different liability in connection
with this product.

Terms And Conditions Of The Warranty

For One Year from date of purchase, we will replace any original component provided by Champion
Cooler which fails due to any defect in material or factory workmanship only.

Exclusions From The Warranty

We are not responsible for replacement of evaporative media. These are disposable components and
should be replaced periodically. We are not responsible for any incidental or consequential damage result-
ing from any malfunction.

We are not responsible for any damage received from the use of water softeners, chemicals, de-scale mate-
rial or plastic wrap.

We are not responsible for the cost of service calls to diagnose the cause of trouble, or labor charge to
repair and/or replace parts.

How To Obtain Service Under This Warranty

Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satisfi ed
with the response from the dealer, contact the Customer Service Department: Champion Cooler, 5800
Murray Street, Little Rock, Arkansas 72209. 1-800-643-8341. [email protected]

This limited warranty applies to the original purchaser only.

Register your product online at www.championcooler.com/eac/onlineregistration-eac.htm

Maintenance

WARNING: Before doing any maintenance be sure unit is unplugged.

Drain Unit

Note: To remove the media frame, fi rst remove the screw located above the frame.
To drain the unit, remove the media frame and remove the rubber drain stopper from the bottom of the unit
by pulling it out of the drain hole. The unit should be drained periodically to keep the water fresh. We
recommend draining the unit once a week. Drain the water from the unit when it will not be used for an
extended period.

Clean/Replace Evaporative Media

The evaporative media should be cleaned twice a season or when
needed. To clean the media, rinse with clean water. Light scrub-
bing might be necessary. Be careful not to damage media. After
about 2 years, or when it becomes clogged, the media will need to be
replaced. To remove the media, press the end of the keeper stem to
push it through the keeper disk (see fi g. 4). This plastic disk will need
to be removed in order to remove the media.

When replacing the evaporative media, install it so that the steeper
fl ute angle of the media is sloping down towards the media frame (see
fi g. 4). Push the keeper stems through the media from the back of the
media frame and press the keeper disks onto the stems to secure the
media in place.

45°

15°

Keeper

Disk

Keeper

Stem

Fig. 4

3