PELLET STOVES

Chapter 3

INSTALLATION AND USE MANUAL

page

29

Installation and assembly

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

Hardness of water circulating in the system, to prevent

problems of incrustation and limescale, especially in the

domestic water heat exchanger. (> 25° French)

Installation of a water softener (if water hardness

exceeds 25° French)

Filling the system with treated water (demineralised).

Possibly providing an anti-condensation circuit.

Installation of plumbing bumpers to prevent banging

along the fittings and pipes.

If you have very extensive systems, with a large amount of water, or

which require frequent refilling, the installation of water softening

systems.

It should be remembered that incrustations

drastically reduce performance due to low thermal

conductivity.

3.5. EXAMPLE INSTALLATION DIAGRAMS

The following diagrams are to be used only as a

guideline. For proper connection, always follow the

notes for the plumbing and heating installer. The

plumbing system must meet local, regional or

national requirements. Installation and verification

of operation is to be performed only by specialized,

authorized personnel.
MCZ will not be held liable for non-compliance with

the provisions listed above.

Advertising