The colour is in some ways linked to the shape of the flame. A colour

which varies from orange to yellow, with dark tips to the flame, is liable

to be a swollen flame (as described above), lacking in oxygen or at

least indicative of faulty combustion. As the colour changes towards

light yellow - white, the shape of the flame alters, becoming thinner

and showing the presence of higher levels of oxygen.

4.9.3. The character

Liveliness or weakness is in any case closely connected to the shape of

the flame.

4.10. OPERATION

4.10.1. Operating concept

When you light the stove using the button

r

, after the initial ignition

phase of about 15 minutes, during which the display (8) shows the

intermediate phases “FAN ACC – LOAD WOOD – FIRE ON“, the stove

will start running in AUTOMATIC mode at medium power, and it will

make a first check of the temperature to be reached.
The ambient temperature is shown on the upper display (8) of the

panel, whereas the temperature of the water in the boiler is indicated

on the lower one alternating with the message H

2

O

In this operating mode, you can vary only the desired room
temperature using the buttons

n

and

o

.

The main purpose of the stove is to bring the room

temperature as measured by the thermostat (internal or

external) up to the temperature set by the user.

Then, based on the room temperature, it performs the

following evaluation:

Room temperature < Thermostat temperature ?

YES
This means that the stove must heat the room. Therefore, it will

begin gradually raising its flame power until it is at its maximum.

NO
This means that the stove has achieved its objective in heating the

room. Therefore, it will decrease its power to a minimum, and it

will leave it there until the room temperature again drops below

the temperature set in the thermostat, unless the ECO-STO

function is enabled (see paragraph 4.9.3)

For proper operation, it is indispensable for the room

thermostat (internal or external) to measure the

temperature reliably, since the correct operation is

based almost exclusively on the aforementioned

control.

INCORRECT COMBUSTION
Shape:
swollen, overflowing, not compact
Character:
Weak - feeble
Colour:
Orange - yellow

Adjustment of thermostat temperature (temperature to

be reached in the room)

SET

TUR BO

1

2

6

4

3

5

!

SET

22°C

SET

TURBO

1

2

6

4

3

5

!

18°C

43°C

Stove on and working at full power

NORMAL COMBUSTION
Shape:
Tapered, vertical, compact
Character:
Lively
Colour:
Yellow - Light yellow - White