Back of the rack mounting, Mtp u r series • installation, Figure 8 — mounting the mtp on a versatools shelf – Extron Electronics MTP U R RS User Manual

Page 12

Advertising
background image

MTP U R Series • Installation

• RSU 129, 9.5" deep Universal 1U rack shelf kit

(part #60-190-01)

• RSB 129, 9.5” deep Basic 1U rack shelf (part #60-604-01)
On the standard rack shelf, the MTP U R mounts in one of four

locations to the rear of the rack or in one of four locations to the

front of the rack.

(2) 4-40 x 3/16" Screws

Use 2 mounting holes on

opposite corners.

VersaTools Basic
Rack Shelf

Quarter Rack Width False

Faceplate

MTP T V

GA RS

MTP

T V

GA R

S

MTP

T V

GA R

S

Figure 8 — Mounting the MTP on a VersaTools shelf

1

. Remove the feet from the bottom of the MTP, if they are

installed.

2

.

Mount the MTP using two 4-40 x 3/16" screws in opposite

(diagonal) corners to secure the MTP to the shelf.

N

Fxtron recommends where more than one shelf is

required, rack mount shelves are installed at least 1U

apart, to allow for air flow and proper cooling between

the shelves.

3

.

Install false faceplate(s) or other unit(s) to the rack shelf.

4.

Mount the shelf into the rack.

Back of the rack mounting

The MTP can be mounted to the rear of a rack using the Extron

MBB 100, VersaTools

®

back of the rack mounting kit

(part #70-367-01). The kit allows the product to be vertically

mounted to the front or rear rack supports and facing either

towards the front or the rear of the rack.

9