Power supply wiring

N

This product should be connected to a UL Listed power

supply and output rated at 12 VDC, 2A.

Wire the supplied male power connector (plug) as in figure 15.

Power Supply

Output

Cord

Captive

Screw

Connector

SECTION A–A

Ridges

Smooth

A

A

Tie Wrap

3"

16 (5 mm) Max.

Figure 15 — Power connector wiring

To verify the polarity before connection, plug in the power
supply with no load and check the output with a voltmeter.

C

Power supply voltage polarity is critical. Incorrect
voltage polarity can damage the power supply and
the product. If a voltmeter is not available, identify
the power cord negative lead by the ridges on the
side of the cord.

N

The length of the exposed (stripped) copper wires is

important. The ideal length is 3/16 (5 mm). Longer

bare wires can short together. Shorter wires are not

as secure in the captive screw connectors and could be

pulled out.

Do not tin the stripped power supply leads before

installing the captive screw connector. Tinned wires are

not as secure in the captive screw connectors and could

be pulled out.

W

The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before wiring.

As an alternative, an Extron P/S 123 Universal 12 VDC Power

Supply, part #60-814-01, can power multiple MTPs or other

Extron 12 VDC devices using only one AC power connector.
Insert the wired plug into the power connector on the rear panel.