N

A 2-nanosecond (ns) adjustment is very fine. Up to

10 ns of delay may be necessary before a change in the

display is detectable. Maximum delay possible is 62

nanoseconds.

c

. Use a Tweeker or other small screwdriver to press the

Select button one more time to save the most recent

adjustment or allow the 10-second timeout to elapse.

4.

If the remaining color is left shifted, repeat step 3.

Non-SEQ receivers skew compensation

Try using the following methods to minimize or eliminate pair

skew:
• Switch to Extron’s Enhanced Skew-Free A/V UTP cable.
• Add a skew compensation cable equal to the length of

pair skew to the receiver’s output.

• Install an SEQ 100 15HD Skew Equalizer on the receiver’s

video output and adjust the skew for the leading video

image.

21