Introduction, cont’d – Extron Electronics MTP U R RS User Manual

Page 9

Advertising
background image

Introduction, cont’d

MTP U R Series • Introduction

6

5

.

Reinstall the four screws removed in step 2. If any

mounting brackets were removed in step 1, put them back

into position as you reinstall the screws

6

.

If applicable, reinstall the receiver and reconnect all cables.

N

JMP1 should be set to unidirectional when an

MTP DA is installed as part of the system to avoid any

RS-232 /Audio detection issues.

When an MTP U R series receiver is used with an

MTPX Matrix Switcher, JMP1 should be set to

unidirectional for transmitter to receiver communication,

otherwise it should be set to bi-directional when using

the RS-232 output insert connections on the switcher.

Setting JMP2 and JMP3 to positive vertical and/or

horizontal sync polarity

JMP2 controls vertical sync, and JMP controls horizontal sync,

and are to the left of JMP 1, when viewed from the rear of the

receiver. By default they are set to open (a single pin covered).

They can be repositioned to invert vertical or horizontal sync as

follows:
1

.

If the unit is not already open, follow steps 1 and 2 on the

previous page to access the jumpers.

2

.

Locate JMP2 and JMP3 on the main board. Remove and

reposition the jumper block over both pins (see figure 4).

Reposition the jumper
block to cover both pins.

Figure 4 — Inverting sync with jumpers JMP2 and 3

3

.

Replace the top cover and follow steps 5 and 6 above.

To reset the syncs to default, open the unit and turn the

applicable jumper block to cover only a single pin, as desired.

Advertising