MEDC SM87HXB User Manual

Page 5

Advertising
background image

5.0 CERTIFICATION/APPROVALS
IECEx units

Certified to IEC 60079-0, IEC 60079-1 and IEC 60079-31

Ex d unit (IEC certification No. IECEx BAS 09.0059)

Ex d IIC Tx (Tamb.) Gb
Ex tb IIIC Tx (Tamb.) Db IP66/IP67

Unit type

T-rating (Tx) Ambient temp range (Tamb.)

SM87HXB

T95°C

(-55°C to +70°C)

T80°C

(-55°C to +55°C)

T65°C

(-55°C to +40°C)

SM87XBT/A (Electronics)

T70°C

(-55°C to +55°C)

T55°C

(-55°C to +40°C)

SM87XBT/B (Xenon tube)

T110°C

(-55°C to +85°C)

T95°C

(-55°C to +70°C)

T80°C

(-55°C to +55°C)

T65°C

(-55°C to +40°C)

The IECEx certificate and product label carry the IECEx equipment protection level marking

Gb
Db

Where Gb signifies suitability for use in a Zone 1 surface industries area in the presence of gas.
Where Db signifies suitability for use in a Zone 21 surface industries area in the presence of dust.

ATEX units

Certified to EN60079-0, EN60079-1 and EN60079-31

Ex d unit (ATEX certification No. Baseefa03ATEX0222)

Ex d IIC Tx (Tamb.) Gb
Ex tb IIIC Tx (Tamb.) Db IP66/IP67

Unit type

T-rating (Tx) Ambient temp range (Tamb.)

SM87HXB

T95°C

(-55°C to +70°C)

T80°C

(-55°C to +55°C)

T65°C

(-55°C to +40°C)

SM87XBT/A (Electronics)

T70°C

(-55°C to +55°C)

T55°C

(-55°C to +40°C)

SM87XBT/B (Xenon tube)

T110°C

(-55°C to +85°C)

T95°C

(-55°C to +70°C)

T80°C

(-55°C to +55°C)

T65°C

(-55°C to +40°C)

© Cooper MEDC 2011