Access to Terminals

Unscrew the 3 off M5 screws (4.0mm A/F hexagon key) holding the cover assembly to the base. The screws are

retained in the cover. Remove cover to gain access to the interior of the terminal chamber.

Once termination is complete, carefully replace the cover back onto the enclosure, avoiding damage to the mating

surfaces. Evenly tighten the 3 off M5 screws (4.0mm A/F hexagon key) in the cover, ensuring the O-ring is

correctly seated in its groove during re-assembly

4.0 OPERATION

The operating voltage of the unit is stated on the unit label.

Different sound levels can be obtained by selecting the transformer tappings in the unit, via the terminals in the

Exe chamber. See table below for available tappings:

POWER!

TRANSFORMER

TAPPINGS!

30W

VERSION!

25W

VERSION!

1:2!

30W!

25W!

2:3!

25W!

12.5W!

3:4!

12W!

6W!

1:3!

6W!

4W!

2:4!

4W!

2W!

1:4!

2W!

1W!

GENERAL ARRANGEMENT

5.0 MAINTENANCE

During the working life of the unit, it should require little or no maintenance. GRP will resist attack by most acids,

alkalis and chemicals and is as resistant to concentrated acids and alkalis as most metal products.

However, if abnormal or unusual environmental conditions occur due to plant damage or accident etc., then visual

inspection is recommended.

If a unit fault should occur, then the unit can be repaired by MEDC. All parts of the unit are replaceable.

If you acquired a significant quantity of units, then it is recommended that spares are also made available.

Please discuss your requirements with the Technical Sales Engineers at MEDC.