LED & Xenon Units

Certified to EN60079-0 , EN60079-7, and EN60079-18

Ex e mb IIC T4 Gb (-40°C to +45°C ) - LED

Ex e mb IIC T4 Gb (-40°C to +55°C ) - Xenon



The ATEX certificate and product label carry the ATEX group and category marking:

II 2 G

Where:

Signifies compliance with ATEX

II Signifies suitability for use in surface industries

2

Signifies suitability for use in a zone 1 area

G Signifies suitability for use in the presence of gases



These units also have the following approvals:

Ingress protection: IP66 & IP67 to IEC60529


7.0 SPECIAL CONDITIONS FOR SAFE USE

1. All terminals, whether used or not, shall be fully tightened down.

2. Interconnected units must be of the same electrical rating.

3. The terminals shall only be installed and wired with cable in a temperature range of -10°C to +80°C.

4. The cable entry devices used on the equipment shall be suitably IECEx/ATEX equipment certified and

maintain the IP54 minimum of the enclosure. Unused cable entries must be fitted with suitable

IECEx/ATEX equipment certified stopping plugs that maintain the IP54 minimum of the enclosure.

5. The equipment shall be connected by a supply with a 1500A short-circuit capable fuse