Precision Flight Elevator Potentiometer User Manual

Page 3

Advertising
background image

7. Using a ½ inch wrench, remove the bridge bolt. (see picture above)

8. Using a 7/16 wrench, remove the Z bracket bolt. (see above)

9. Cut the wires to the pitch potentiometer. Cut the wires as close to the potentiometer as you can.

10. Remove the setscrew and pull the Z bracket and potentiometer out. Make sure not to bend the Z-

bracket.

11. Remove the old potentiometer and install the new one on the Z bracket. Do not tighten completely yet.

12. Slide the potentiometer in the pulley, pins should point away from the yoke. Do not install allen screw

yet.

Advertising