ProSYS Version 8.xx - Supplementary Instructions

BUS Zone Parameters: iWISE QUAD Grade 3

Quick Keys

Parameter

Default

Range

[2][0][3][zz][5]
[1]

Remote (manual)

The remote self test is performed by the system when a user manually
selects the Diagnostics option from the Maintenance menu via the ProSYS
User Functions menu.

[2][0][3][zz][5]
[2]

Local (automatic)

Once an hour, the detector automatically checks that the detector’s channels
are functioning properly.

BUS Detector Naming Conventions

The following table contains the names of the various BUS detectors and their corresponding
Engineer programming menu codes under the Type field, when adding a new BUS zone to the
system.

BUS Detector

TYPE Field Option
in Previous Versions

TYPE Field Option
in Version 7 and above

WatchOUT DT

ODT15

ODT15

WatchOUT PIR

OPR12

OPR12

Industrial LuNAR

LUNR

Cannot be selected,
Replaced by Industrial
LuNAR Grade 3.

Industrial LuNAR Grade 3

LUNG3

ILun3

WatchIN IDT25

WatIN

iWISE DT G2 BUS 15m, 25m

N/A

iDTG2

iWISE QUAD G2 BUS

N/A

IQUG2

iWISE DT G3 BUS 15m, 25m

N/A

iDTG3

iWISE QUAD G3 BUS

N/A

IQUG3

New Firmware Capabilities

The information in this section describes new capabilities in the ProSYS firmware and new
parameters under the Engineer programming menu.

WatchOUT Proximity Anti Mask

WatchOUT DT version B (P/N RK325DT00UKB) has a new proximity anti masking capability in
addition to its regular IR anti masking capability.

When the WatchOUT DT is installed as a BUS zone, in order to enable Proximity Anti-Mask the
following parameters must be programmed: