RISCO Group ProSYS Version 8.xx User Manual

Page 6

Advertising
background image

6

ProSYS Version 8.xx - Supplementary Instructions

BUS Zone Parameters: iWISE DT Grade 2

Quick Keys

Parameter

Default

Range

[2][0][3][zz]
[1]

LEDS

On

Defines the LEDS operation mode.

[2][0][3][zz]
[1] [1] to [2]

LEDS Options

1) Off - Disables the LEDS operation.
2) On – Enables the LEDS operation.

[2][0][3][zz]
[2]

MW (Microwave) Range

Trimmer

Defines the microwave channel range.

[2][0][3][zz]
[2] [1] to [7]

MW Range Options

1) Minimum 2) 25% 3) 50% 4) 65% 5) 85% 6) Maximum 7) Trimmer (MW is
defined by the trimmer setting on the PCB)

[2][0][3][zz]
[3]

ACT

No

Defines the Anti-Cloak™ Technology (ACT) operation mode.

[2][0][3][zz]
[3] [1] to [2]

ACT Options

1) No - Disables the ACT mode.
2) Yes – Enables the ACT mode.

[2][0][3][zz]
[4]

Automatic Microwave Omit

No

Defines whether the MW channel will be bypassed or not while the detector
identifies trouble in the MW channel.

[2][0][3][zz]
[4] [1] to [2]

Automatic Microwave Omit

Options

1) No - While detecting a problem in the MW channel it is not omitted. Alarm
condition cannot be established until the MW channel is fixed.
2) Yes - Switches the detector to operate only in PIR mode in case of MW
trouble.

[2][0][3][zz]
[5]

Green Line

No

A feature that follows environmental guidelines by avoiding surplus emission.
This feature defines the activation of the microwave channel while the system
is disarmed.

[2][0][3][zz]
[5] [1] to [2]

Green Line Options

1) No - Green Line feature is disabled. MW is constantly activated.
2) Yes – Green Line feature is activated.

[2][0][3][zz]
[6]

Self Test

Remote

Used to test the detection technologies. In the event of a failed test, a Self
Test Trouble is created.

[2][0][3][zz]
[6][1]

Remote (manual)

The remote self test is performed by the system when a user manually
selects the Diagnostics option from the Maintenance menu via the ProSYS
User Functions menu.