9

S4500THS User Guide

Portable Printing Solutions

Extech Instruments Corporation 285 Bear Hill Road, Waltham, MA 02451-1064 Phone: 1-877-4-EXTECH (439-8324) Fax: (781) 890-7864 Web site: www.extech.com

Copyright © 2005 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form.

3.2.2 S

ETTING

D

IP

S

WITCHES

EXAMPLE: D

IP

S

WITCH

#1

SHOWN

IN

ON

POSITION

Note: Be careful when changing dip switch settings. Carefully use a

pointer on the dip switch you are going to change. DO NOT use a
screw driver or apply excessive force.

3.2.3 D

IP

S

WITCH

F

UNCTIONS

Note: (Developer’s refer to Programming Manual for more information)

Dip Switch

Function

Switch

Switch

Switch

LED Indication

1 & 2

Communication Interface

SW1

SW2

RS 232

Off

Off

Flashing Green

IrDA

On

Off

Flashing Green

Bluetooth

Off

On

Flashing Blue

802.11b

On

On

Flashing Orange

3, 4 & 5

Baud Rate

SW3

SW4

SW5

115200

Off

Off

Off

57600

On

Off

Off

38400

Off

On

Off

19200

On

On

Off

14400

Off

Off

On

9600

On

Off

On

2400

Off

On

On

1200

On

On

On

6

Parity Bit

SW6

Parity Enabled

On

Parity Disabled

Off

7

Odd/Even

SW7

Odd Parity

On

Even Parity

Off

8

Auto Power Save

SW8

Power save disabled

On

Power save enabled

Off

T

ABLE

2 – DIP S

WITCH

S

ETTING

Please note:

In order for changes to the dip switch configuration to take effect, the printer power
must be reset. This action occurs automatically when the battery is removed to
gain access to the dip switches.